| Assessment Year | 1993 |
|---|---|
| Principal Product | Printed Cartons & Boxes |
| NAICS |
n/a
|
| SIC | 2631: Paperboard Mills |
| Sales Range | $1 M to 5M |
| # of Employees | 75 |
| Plant Area |
138,000
ft2
|
| Annual Production | 2,300,000
lb
|
| Production Hrs. Annual | 5,214
hrs
|
| Location (State) | Arkansas |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $171,222 | 1,935,522 |
kWh
|
$0.088 |
| Natural Gas | $24,990 | 5,842 |
MMBtu
|
$4.28 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $9,391 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $9,391 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings |
|---|---|---|---|---|---|
| 01 | 2.4221: Install compressor air intakes in coolest locations | $180 | $60 |
$180
2,052
kWh
|
|
| 02 | 2.7111: Reduce illumination to minimum necessary levels | $2,924 | $90 |
$2,924
32,825
kWh
|
|
| 03 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $4,831 | $678 |
$4,831
54,513
kWh
|
|
| 04 | 2.4133: Use most efficient type of electric motors | $1,456 | $3,500 |
$1,456
16,413
kWh
|
|
| TOTAL RECOMMENDED | $9,391 | $4,328 |
$9,391
105,803
kWh
|
||
| TOTAL IMPLEMENTED | $9,391 | $4,328 |
$9,391
105,803
kWh
|
||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs