| Assessment Year | 2026 |
|---|---|
| Principal Product | Corn Tortillas, Flour Tortillas and Chips |
| NAICS | 311830: Tortilla Manufacturing |
| SIC | 2099: Food Preparations, Not Elsewhere Classified |
| Sales Range | $10 M to 50M |
| # of Employees | 108 |
| Plant Area |
10,000
ft2
|
| Annual Production | 16,000
ton
|
| Production Hrs. Annual | 3,341
hrs
|
| Location (State) | Texas |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | ||
|---|---|---|---|---|---|
| Electricity Usage | $177,906 | 3,141,217 |
kWh
|
$0.057 | |
| Electricity Demand | $90,610 | 10,410 |
kW-mo/yr
|
$8.70 | |
| Electricity Fees | $11,588 | - |
|
- | |
| Natural Gas | $169,959 | 47,632 |
MMBtu
|
$3.57 | |
| Waste Disposal Costs | |||||
| Water Usage | $81,080 | 9,696 |
Tgal
|
$8.36 | |
| Water Disposal | $73,110 | 9,696 |
Tgal
|
$7.54 | |
| TOTAL YEARLY COSTS | $604,253 | ||||
| RECOMMENDED SAVINGS* | $163,463 |
See individual recommendations below
*Non-energy impacts included in savings.
|
|||
| IMPLEMENTED SAVINGS* | - | ||||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Water Disposal Savings |
|---|---|---|---|---|---|---|---|
| 01 | 2.3212: Optimize plant power factor | $5,740 | $10,270 | - |
$5,740
-
kW-mo/yr
|
- | |
| 02 | 3.4116: Meter recycled water (to reduce sewer charges) | $40,935 | - | - | - |
$40,935
-
Tgal
|
|
| 03 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $761 | $545 |
$489
8,732
kWh
|
$272
-
kW-mo/yr
|
- | |
| 04 | 2.4239: Eliminate or reduce compressed air usage | $360 | $425 |
$360
6,430
kWh
|
- | - | |
| 05 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $4,666 | $1,830 |
$3,970
58,100
kWh
|
$696
-
kW-mo/yr
|
- | |
| 06 | 2.4231: Reduce the pressure of compressed air to the minimum required | $971 | $9 |
$622
11,114
kWh
|
$349
-
kW-mo/yr
|
- | |
| 07 | 2.6218: Turn off equipment when not in use | $8,900 | $540 |
$8,900
158,500
kWh
|
- | - | |
| 08 | 2.9114: Use solar heat to make electricty | $101,130 | $815,980 |
$101,130
1,446,598
kWh
|
- | - | |
| TOTAL RECOMMENDED | $163,463 | $829,599 |
$115,471
1,689,474
kWh
|
$7,057
-
kW-mo/yr
|
$40,935
-
Tgal
|
||
| TOTAL IMPLEMENTED | - | - | - | - | - | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Water Disposal Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs