| Assessment Year | 2026 |
|---|---|
| Principal Product | Custom wood and stone furniture and furnishings |
| NAICS | 337212: Custom Architectural Woodwork and Millwork Manufacturing |
| SIC | 2431: Millwork |
| Sales Range | $10 M to 50M |
| # of Employees | 90 |
| Plant Area |
60,000
ft2
|
| Annual Production | 3,500
pieces
|
| Production Hrs. Annual | 2,185
hrs
|
| Location (State) | Texas |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $47,080 | 678,012 |
kWh
|
$0.069 |
| Electricity Demand | $33,089 | 3,372 |
kW-mo/yr
|
$9.81 |
| Electricity Fees | $10,451 | - |
|
- |
| LPG | $12,725 | 256 |
MMBtu
|
$49.71 |
| Fuel Oil #1 | $2,484 | 120 |
MMBtu
|
$20.70 |
| TOTAL YEARLY COSTS | $105,829 | |||
| RECOMMENDED SAVINGS* | $44,845 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | - | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Personnel Changes Savings | Ancillary Material Cost Savings | One-time Revenue or Avoided Cost Savings |
|---|---|---|---|---|---|---|---|---|---|---|
| 01 | 2.8121: Apply for tax-free status for energy purchases | $31,260 | $5,220 | - | - | $6,260 | - | - | $25,000 | |
| 02 | 2.3212: Optimize plant power factor | $3,130 | $3,310 | - |
$3,130
-
kW-mo/yr
|
- | - | - | - | |
| 03 | 2.6218: Turn off equipment when not in use | $3,398 | $80 |
$4,410
65,800
kWh
|
- | - | $(-1,012.0) | - | - | |
| 04 | 2.8112: Combine utility meters | $3,270 | $3,250 | - | - | $3,270 | - | - | - | |
| 05 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $1,725 | $4,060 |
$766
11,400
kWh
|
$716
-
kW-mo/yr
|
- | - | $243 | - | |
| 06 | 2.4231: Reduce the pressure of compressed air to the minimum required | $1,077 | $30 |
$557
8,310
kWh
|
$520
-
kW-mo/yr
|
- | - | - | - | |
| 07 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $985 | $504 |
$509
7,600
kWh
|
$476
-
kW-mo/yr
|
- | - | - | - | |
| TOTAL RECOMMENDED | $44,845 | $16,454 |
$6,242
93,110
kWh
|
$4,842
-
kW-mo/yr
|
$9,530 | $(-1,012.0) | $243 | $25,000 | ||
| TOTAL IMPLEMENTED | - | - | - | - | - | - | - | - | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Personnel Changes Savings | Ancillary Material Cost Savings | One-time Revenue or Avoided Cost Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs