| Assessment Year | 2025 |
|---|---|
| Principal Product | wine |
| NAICS | 312130: Wineries |
| SIC | 2084: Wines, Brandy, and Brandy Spirits |
| Sales Range | $5 M to 10M |
| # of Employees | 30 |
| Plant Area |
40,000
ft2
|
| Annual Production | 170
Tgal
|
| Production Hrs. Annual | 2,572
hrs
|
| Location (State) | Texas |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | ||
|---|---|---|---|---|---|
| Electricity Usage | $33,500 | 706,000 |
kWh
|
$0.047 | |
| Electricity Demand | $21,000 | 2,320 |
kW-mo/yr
|
$9.05 | |
| Other Gas | $11,700 | 514 |
MMBtu
|
$22.76 | |
| Waste Disposal Costs | |||||
| Water Usage | $10,800 | 1,047 |
Tgal
|
$10.32 | |
| TOTAL YEARLY COSTS | $77,000 | ||||
| RECOMMENDED SAVINGS* | $23,031 |
See individual recommendations below
*Non-energy impacts included in savings.
|
|||
| IMPLEMENTED SAVINGS* | - | ||||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | One-time Revenue or Avoided Cost Savings |
|---|---|---|---|---|---|---|---|---|
| 01 | 2.2511: Insulate bare equipment | $211 | $30 |
$188
4,000
kWh
|
$23
-
kW-mo/yr
|
- | - | |
| 02 | 2.2515: Use optimum thickness insulation | $380 | $580 |
$290
6,200
kWh
|
$90
-
kW-mo/yr
|
- | - | |
| 03 | 2.2533: Replace air curtain doors with solid doors | $1,690 | $3,000 |
$1,690
36,000
kWh
|
- | - | - | |
| 04 | 2.8121: Apply for tax-free status for energy purchases | $11,400 | $15,000 | - | - | $2,300 | $9,100 | |
| 05 | 2.7423: Reduce heat gain by window tinting | $550 | $3,400 |
$330
6,900
kWh
|
$220
-
kW-mo/yr
|
- | - | |
| 06 | 2.7491: Insulate glazing, walls, ceilings, and roofs | $1,515 | $21,320 |
$1,200
25,500
kWh
|
$315
-
kW-mo/yr
|
- | - | |
| 07 | 2.9114: Use solar heat to make electricty | $7,285 | $187,000 |
$7,285
155,000
kWh
|
- | - | - | |
| TOTAL RECOMMENDED | $23,031 | $230,330 |
$10,983
233,600
kWh
|
$648
-
kW-mo/yr
|
$2,300 | $9,100 | ||
| TOTAL IMPLEMENTED | - | - | - | - | - | - | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | One-time Revenue or Avoided Cost Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs