Assessment Year | 2025 |
---|---|
Principal Product | students |
NAICS | 611110: Elementary and Secondary Schools |
SIC | 8211: Elementary and Secondary Schools |
Sales Range | $1 M to 5M |
# of Employees | 52 |
Plant Area |
53,087
ft2
|
Annual Production | 150
units
|
Production Hrs. Annual | 2,656
hrs
|
Location (State) | Texas |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $16,515 | 434,600 |
kWh
|
$0.038 |
Electricity Demand | $28,084 | 2,136 |
kW-mo/yr
|
$13.15 |
Natural Gas | $8,504 | 833 |
MMBtu
|
$10.21 |
TOTAL YEARLY COSTS | $53,103 | |||
RECOMMENDED SAVINGS* | $15,514 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | - |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings |
---|---|---|---|---|---|---|---|
01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $349 | $1,474 |
$139
3,650
kWh
|
$210
-
kW-mo/yr
|
- | |
02 | 2.7135: Install occupancy sensors | $485 | $1,668 |
$169
4,436
kWh
|
$316
-
kW-mo/yr
|
- | |
03 | 2.7493: Use double or triple glazed windows to maintain higher relative humidity and to reduce heat losses | $2,639 | $69,318 |
$696
18,323
kWh
|
- |
$1,943
-
MMBtu
|
|
04 | 2.9114: Use solar heat to make electricty | $12,041 | $229,320 |
$12,041
316,881
kWh
|
- | - | |
TOTAL RECOMMENDED | $15,514 | $301,780 |
$13,045
343,290
kWh
|
$526
-
kW-mo/yr
|
$1,943
-
MMBtu
|
||
TOTAL IMPLEMENTED | - | - | - | - | - |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs