| Assessment Year | 2025 | 
|---|---|
| Principal Product | Electric Motors | 
| NAICS | 335312: Motor and Generator Manufacturing | 
| SIC | 3621: Motors and Generators | 
| Sales Range | less than $500 k  | 
    
| # of Employees | 235 | 
| Plant Area | 
                            420,000
                 
ft2
 
                     | 
    
| Annual Production | 350
             
units
 
         | 
    
| Production Hrs. Annual | 2,084
             
hrs
 
         | 
    
| Location (State) | Texas | 
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | ||
|---|---|---|---|---|---|
| Electricity Usage | $813,428 | 14,281,034 | 
             
kWh
 
         | 
        $0.057 | |
| Electricity Demand | $271,226 | 62,182 | 
             
kW-mo/yr
 
         | 
        $4.36 | |
| Electricity Fees | $35,504 | - | 
             | 
        - | |
| Natural Gas | $51,498 | 7,621 | 
             
MMBtu
 
         | 
        $6.76 | |
| Waste Disposal Costs | |||||
| Water Usage | $86,717 | 8,700 | 
             
Tgal
 
         | 
        $9.97 | |
| TOTAL YEARLY COSTS | $1,258,373 | ||||
| RECOMMENDED SAVINGS* | $259,136 | 
             See individual recommendations below 
            *Non-energy impacts included in savings.
         | 
    |||
| IMPLEMENTED SAVINGS* | - | ||||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Natural Gas Savings | One-time Revenue or Avoided Cost Savings | 
|---|---|---|---|---|---|---|---|---|---|
| 01 | 2.8121: Apply for tax-free status for energy purchases | $130,091 | $15,000 | - | - | $97,511 | - | $32,580 | |
| 02 | 2.1233: Analyze flue gas for proper air/fuel ratio | $12,879 | $2,550 | - | - | - | 
                        $12,879
                                                     -
                                 
                                            
MMBtu
 
                             | 
                                                                                - | |
| 03 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $30,166 | $1,100 | 
                        $29,900
                                                     533,900
                                 
                                            
kWh
 
                             | 
                                                                                
                        $266
                                                     -
                                 
                                            
kW-mo/yr
 
                             | 
                                                                                - | - | - | |
| 04 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $4,720 | $9,710 | 
                        $4,720
                                                     84,200
                                 
                                            
kWh
 
                             | 
                                                                                - | - | - | - | |
| 05 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $5,140 | $61,488 | 
                        $3,075
                                                     54,918
                                 
                                            
kWh
 
                             | 
                                                                                
                        $1,723
                                                     -
                                 
                                            
kW-mo/yr
 
                             | 
                                                                                - | - | $342 | |
| 06 | 2.4234: Cool compressor air intake with heat exchanger | $1,748 | $2,063 | 
                        $1,748
                                                     31,220
                                 
                                            
kWh
 
                             | 
                                                                                - | - | - | - | |
| 07 | 2.9114: Use solar heat to make electricty | $74,392 | $829,317 | 
                        $74,392
                                                     1,305,119
                                 
                                            
kWh
 
                             | 
                                                                                - | - | - | - | |
| TOTAL RECOMMENDED | $259,136 | $921,228 | 
                        $113,835
                                                     2,009,357
                                 
                                            
kWh
 
                             | 
                                                                                
                        $1,989
                                                     -
                                 
                                            
kW-mo/yr
 
                             | 
                                                                                $97,511 | 
                        $12,879
                                                     -
                                 
                                            
MMBtu
 
                             | 
                                                                                $32,922 | ||
| TOTAL IMPLEMENTED | - | - | - | - | - | - | - | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Natural Gas Savings | One-time Revenue or Avoided Cost Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs