| Assessment Year | 2025 |
|---|---|
| Principal Product | Electric Motors |
| NAICS | 335312: Motor and Generator Manufacturing |
| SIC | 3621: Motors and Generators |
| Sales Range | less than $500 k |
| # of Employees | 235 |
| Plant Area |
420,000
ft2
|
| Annual Production | 350
units
|
| Production Hrs. Annual | 2,084
hrs
|
| Location (State) | Texas |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | ||
|---|---|---|---|---|---|
| Electricity Usage | $813,428 | 14,281,034 |
kWh
|
$0.057 | |
| Electricity Demand | $271,226 | 62,182 |
kW-mo/yr
|
$4.36 | |
| Electricity Fees | $35,504 | - |
|
- | |
| Natural Gas | $51,498 | 7,621 |
MMBtu
|
$6.76 | |
| Waste Disposal Costs | |||||
| Water Usage | $86,717 | 8,700 |
Tgal
|
$9.97 | |
| TOTAL YEARLY COSTS | $1,258,373 | ||||
| RECOMMENDED SAVINGS* | $259,136 |
See individual recommendations below
*Non-energy impacts included in savings.
|
|||
| IMPLEMENTED SAVINGS* | - | ||||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Natural Gas Savings | One-time Revenue or Avoided Cost Savings |
|---|---|---|---|---|---|---|---|---|---|
| 01 | 2.8121: Apply for tax-free status for energy purchases | $130,091 | $15,000 | - | - | $97,511 | - | $32,580 | |
| 02 | 2.1233: Analyze flue gas for proper air/fuel ratio | $12,879 | $2,550 | - | - | - |
$12,879
-
MMBtu
|
- | |
| 03 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $30,166 | $1,100 |
$29,900
533,900
kWh
|
$266
-
kW-mo/yr
|
- | - | - | |
| 04 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $4,720 | $9,710 |
$4,720
84,200
kWh
|
- | - | - | - | |
| 05 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $5,140 | $61,488 |
$3,075
54,918
kWh
|
$1,723
-
kW-mo/yr
|
- | - | $342 | |
| 06 | 2.4234: Cool compressor air intake with heat exchanger | $1,748 | $2,063 |
$1,748
31,220
kWh
|
- | - | - | - | |
| 07 | 2.9114: Use solar heat to make electricty | $74,392 | $829,317 |
$74,392
1,305,119
kWh
|
- | - | - | - | |
| TOTAL RECOMMENDED | $259,136 | $921,228 |
$113,835
2,009,357
kWh
|
$1,989
-
kW-mo/yr
|
$97,511 |
$12,879
-
MMBtu
|
$32,922 | ||
| TOTAL IMPLEMENTED | - | - | - | - | - | - | - | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Natural Gas Savings | One-time Revenue or Avoided Cost Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs