Assessment Year 2025
Principal Product Rubber gaskets and seals
NAICS 339991: Gasket, Packing, and Sealing Device Manufacturing
SIC 3083: Laminated Plastics Plate, Sheet, and Profile Shapes
Sales Range $500
k
to 1
M
# of Employees 110
Plant Area 30,000
ft2
Annual Production 600,000
units
Production Hrs. Annual 7,120
hrs
Location (State) Texas

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $177,795 2,424,300
kWh
Electricity Demand $36,864 6,144
kW-mo/yr
Electricity Fees $4,510 -
Waste Disposal Costs
Water Usage $11,283 468
Tgal
TOTAL YEARLY COSTS $230,452
RECOMMENDED SAVINGS* $97,267 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* -

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings One-time Revenue or Avoided Cost Savings
01 2.7232: Replace existing hvac unit with high efficiency model $14,618 $35,305 $10,389
148,417
kWh
$229
-
kW-mo/yr
$4,000
02 2.2515: Use optimum thickness insulation $41,317 $2,173 $41,317
590,242
kWh
- -
03 2.9114: Use solar heat to make electricty $40,760 $332,530 $40,760
555,438
kWh
- -
04 2.4239: Eliminate or reduce compressed air usage $572 $771 $572
8,176
kWh
- -
TOTAL RECOMMENDED $97,267 $370,779 $93,038
1,302,273
kWh
$229
-
kW-mo/yr
$4,000
TOTAL IMPLEMENTED - - - - -
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs