Assessment Year | 2025 |
---|---|
Principal Product | cleaned semiconductors |
NAICS | 334413: Semiconductor and Related Device Manufacturing |
SIC | 3674: Semiconductors and Related Devices |
Sales Range | $100 M to 500M |
# of Employees | 200 |
Plant Area |
120,000
ft2
|
Annual Production | 328,500
units
|
Production Hrs. Annual | 8,760
hrs
|
Location (State) | Texas |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | ||
---|---|---|---|---|---|
Electricity Usage | $299,274 | 7,286,277 |
kWh
|
$0.041 | |
Electricity Demand | $134,997 | 11,280 |
kW-mo/yr
|
$11.97 | |
Electricity Fees | $46,502 | - |
|
- | |
Natural Gas | $19,366 | 1,835 |
MMBtu
|
$10.55 | |
Waste Disposal Costs | |||||
Water Usage | $63,912 | 11,193 |
Tgal
|
$5.71 | |
TOTAL YEARLY COSTS | $564,051 | ||||
RECOMMENDED SAVINGS* | $229,081 |
See individual recommendations below
*Non-energy impacts included in savings.
|
|||
IMPLEMENTED SAVINGS* | - |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Water Usage Savings | Administrative Changes Savings | One-time Revenue or Avoided Cost Savings |
---|---|---|---|---|---|---|---|---|---|---|
01 | 2.8121: Apply for tax-free status for energy purchases | $189,590 | $15,000 | - | - | $37,918 | - | - | $151,672 | |
02 | 2.9114: Use solar heat to make electricty | $15,120 | $137,270 |
$15,120
159,316
kWh
|
- | - | - | - | - | |
03 | 3.4116: Meter recycled water (to reduce sewer charges) | $12,400 | - | - | - | - | - | $12,400 | - | |
04 | 2.7492: Use proper thickness of insulation on building envelope | $6,250 | $42,340 |
$4,470
108,940
kWh
|
$1,780
-
kW-mo/yr
|
- | - | - | - | |
05 | 2.4146: Use adjustable frequency drive or multiple speed motors on existing system | $2,970 | $10,150 |
$2,970
72,480
kWh
|
- | - | - | - | - | |
06 | 3.4113: Treat and reuse rinse waters | $1,240 | $350 | - | - | - |
$1,240
-
Tgal
|
- | - | |
07 | 2.7135: Install occupancy sensors | $1,037 | $376 |
$1,037
25,229
kWh
|
- | - | - | - | - | |
08 | 2.6218: Turn off equipment when not in use | $474 | - |
$474
1,500
kWh
|
- | - | - | - | - | |
TOTAL RECOMMENDED | $229,081 | $205,486 |
$24,071
367,465
kWh
|
$1,780
-
kW-mo/yr
|
$37,918 |
$1,240
-
Tgal
|
$12,400 | $151,672 | ||
TOTAL IMPLEMENTED | - | - | - | - | - | - | - | - | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Water Usage Savings | Administrative Changes Savings | One-time Revenue or Avoided Cost Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs