Assessment Year | 2024 |
---|---|
Principal Product | Kitchen Cabinets |
NAICS | 337110: Wood Kitchen Cabinet and Countertop Manufacturing |
SIC | 2434: Wood Kitchen Cabinets |
Sales Range | $500 k to 1M |
# of Employees | 225 |
Plant Area |
200,000
ft2
|
Annual Production | 200,000
units
|
Production Hrs. Annual | 2,477
hrs
|
Location (State) | Texas |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $211,685 | 4,635,114 |
kWh
|
$0.046 |
Electricity Demand | $201,412 | 20,140 |
kW-mo/yr
|
$10.00 |
Electricity Fees | $45,062 | - |
|
- |
Natural Gas | $47,636 | 4,513 |
MMBtu
|
$10.56 |
TOTAL YEARLY COSTS | $505,795 | |||
RECOMMENDED SAVINGS* | $218,070 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | - |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | One-time Revenue or Avoided Cost Savings |
---|---|---|---|---|---|---|---|---|
01 | 2.8121: Apply for tax-free status for energy purchases | $190,860 | $18,580 | - | - | $38,190 | $152,670 | |
02 | 2.3212: Optimize plant power factor | $22,740 | $22,490 | - |
$22,740
-
kW-mo/yr
|
- | - | |
03 | 2.4231: Reduce the pressure of compressed air to the minimum required | $3,460 | $33 |
$1,660
36,420
kWh
|
$1,800
-
kW-mo/yr
|
- | - | |
04 | 2.7134: Use photocell controls | $410 | $60 |
$200
4,360
kWh
|
$210
-
kW-mo/yr
|
- | - | |
05 | 2.4314: Use synthetic lubricant | $410 | $10 |
$190
3,900
kWh
|
$220
-
kW-mo/yr
|
- | - | |
06 | 2.7135: Install occupancy sensors | $190 | $250 |
$190
4,070
kWh
|
- | - | - | |
TOTAL RECOMMENDED | $218,070 | $41,423 |
$2,240
48,750
kWh
|
$24,970
-
kW-mo/yr
|
$38,190 | $152,670 | ||
TOTAL IMPLEMENTED | - | - | - | - | - | - | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | One-time Revenue or Avoided Cost Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs