Assessment Year | 2024 |
---|---|
Principal Product | Elementary School Students |
NAICS | 611110: Elementary and Secondary Schools |
SIC | 8211: Elementary and Secondary Schools |
Sales Range | $1 M to 5M |
# of Employees | 50 |
Plant Area |
62,000
ft2
|
Annual Production | 100
units
|
Production Hrs. Annual | 3,377
hrs
|
Location (State) | Texas |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $24,322 | 577,728 |
kWh
|
$0.042 |
Electricity Demand | $46,020 | 3,489 |
kW-mo/yr
|
$13.19 |
Natural Gas | $7,434 | 1,140 |
MMBtu
|
$6.52 |
TOTAL YEARLY COSTS | $77,776 | |||
RECOMMENDED SAVINGS* | $22,300 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | - |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings |
---|---|---|---|---|---|---|---|
01 | 3.4154: Eliminate leaks in water lines and valves | $362 | $3,000 |
$105
2,485
kWh
|
- |
$257
-
MMBtu
|
|
02 | 2.9114: Use solar heat to make electricty | $21,840 | $468,000 |
$18,324
435,249
kWh
|
$3,516
-
kW-mo/yr
|
- | |
03 | 2.7212: Install or upgrade insulation on hvac distribution systems | $21 | $300 | - | - |
$21
-
MMBtu
|
|
04 | 2.7135: Install occupancy sensors | $77 | $1,470 |
$36
866
kWh
|
$41
-
kW-mo/yr
|
- | |
TOTAL RECOMMENDED | $22,300 | $472,770 |
$18,465
438,600
kWh
|
$3,557
-
kW-mo/yr
|
$278
-
MMBtu
|
||
TOTAL IMPLEMENTED | - | - | - | - | - |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs