Assessment Year | 2001 |
---|---|
Principal Product | Business Forms |
NAICS |
n/a
|
SIC | 2764: |
Sales Range | $10 M to 50M |
# of Employees | 87 |
Plant Area |
51,000
ft2
|
Annual Production | 2,603
units
|
Production Hrs. Annual | 6,384
hrs
|
Location (State) | Texas |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $106,550 | 2,728,227 |
kWh
|
$0.039 |
Electricity Demand | $55,690 | 6,847 |
kW-mo/yr
|
$8.13 |
Electricity Fees | $7,508 | - |
|
- |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $9,650 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | - |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings |
---|---|---|---|---|---|---|
01 | 2.2523: Reduce infiltration to refrigerated areas; isolate hot equipment from refrigerated areas | $3,925 | - | n/a |
$3,925
108,851
kWh
|
- |
02 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $1,620 | $1,400 | n/a |
$960
26,660
kWh
|
$660
-
kW-mo/yr
|
03 | 2.4314: Use synthetic lubricant | $1,460 | - | n/a |
$865
23,980
kWh
|
$595
-
kW-mo/yr
|
04 | 2.6212: Turn off equipment during breaks, reduce operating time | $1,070 | - | n/a |
$1,070
29,750
kWh
|
- |
05 | 2.7124: Make a practice of turning off lights when not needed | $700 | - | n/a |
$700
19,340
kWh
|
- |
06 | 2.6242: Minimize operation of equipment maintained in standby condition | $645 | - | n/a | - |
$645
-
kW-mo/yr
|
07 | 2.2511: Insulate bare equipment | $230 | $20 | n/a |
$230
6,450
kWh
|
- |
TOTAL RECOMMENDED | $9,650 | $1,420 |
$7,750
215,031
kWh
|
$1,900
-
kW-mo/yr
|
||
TOTAL IMPLEMENTED | - | - | - | - | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs