Assessment Year 2024
Principal Product Countertops
NAICS 337110: Wood Kitchen Cabinet and Countertop Manufacturing
SIC 2541: Wood Office and Store Fixtures, Partitions, Shelving, and Lockers
Sales Range $10
M
to 50
M
# of Employees 55
Plant Area 90,000
ft2
Annual Production 40
thousand feet
Production Hrs. Annual 2,000
hrs
Location (State) Texas

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $77,541 1,736,417
kWh
Electricity Demand $114,503 8,531
kW-mo/yr
Natural Gas $5,240 429
MMBtu
TOTAL YEARLY COSTS $197,284
RECOMMENDED SAVINGS* $10,510 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* -

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings
01 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves $3,680 $1,000 $1,120
25,500
kWh
$2,560
-
kW-mo/yr
02 2.3131: Reschedule plant operations or reduce load to avoid peaks $2,015 - - $2,015
-
kW-mo/yr
03 2.4231: Reduce the pressure of compressed air to the minimum required $1,330 $13 $470
10,700
kWh
$860
-
kW-mo/yr
04 2.6218: Turn off equipment when not in use $955 $235 $955
21,700
kWh
-
05 2.7141: Lower light fixtures in high ceiling areas $795 $1,140 $285
6,480
kWh
$510
-
kW-mo/yr
06 2.4111: Utilize energy-efficient belts and other improved mechanisms $580 - $205
4,615
kWh
$375
-
kW-mo/yr
07 2.7142: Utilize higher efficiency lamps and/or ballasts $495 $655 $495
11,200
kWh
-
08 2.4239: Eliminate or reduce compressed air usage $365 $1,130 $365
8,300
kWh
-
09 2.7142: Utilize higher efficiency lamps and/or ballasts $225 $200 $165
3,735
kWh
$60
-
kW-mo/yr
10 2.7135: Install occupancy sensors $70 $240 $70
1,535
kWh
-
TOTAL RECOMMENDED $10,510 $4,613 $4,130
93,765
kWh
$6,380
-
kW-mo/yr
TOTAL IMPLEMENTED - - - -
Yearly Savings* Imp'd Cost* Electricity Usage Savings Electricity Demand Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs