Assessment Year | 2023 |
---|---|
Principal Product | Secondary School Students |
NAICS | 611110: Elementary and Secondary Schools |
SIC | 8211: Elementary and Secondary Schools |
Sales Range | $1 M to 5M |
# of Employees | 30 |
Plant Area |
80,191
ft2
|
Annual Production | 100
units
|
Production Hrs. Annual | 3,645
hrs
|
Location (State) | Texas |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $53,682 | 846,720 |
kWh
|
$0.063 |
Electricity Demand | $52,510 | 3,972 |
kW-mo/yr
|
$13.22 |
Natural Gas | $14,368 | 1,424 |
MMBtu
|
$10.09 |
TOTAL YEARLY COSTS | $120,560 | |||
RECOMMENDED SAVINGS* | $37,219 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | - |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings |
---|---|---|---|---|---|---|---|
01 | 2.7121: Utilize daylight whenever possible in lieu of artificial light | $2,027 | $11,775 |
$1,148
18,111
kWh
|
$879
-
kW-mo/yr
|
- | |
02 | 2.7492: Use proper thickness of insulation on building envelope | $1,676 | $51,000 |
$537
8,464
kWh
|
- |
$1,139
-
MMBtu
|
|
03 | 2.9114: Use solar heat to make electricty | $33,516 | $534,742 |
$30,402
479,528
kWh
|
$3,114
-
kW-mo/yr
|
- | |
TOTAL RECOMMENDED | $37,219 | $597,517 |
$32,087
506,103
kWh
|
$3,993
-
kW-mo/yr
|
$1,139
-
MMBtu
|
||
TOTAL IMPLEMENTED | - | - | - | - | - |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs