| Assessment Year | 2023 |
|---|---|
| Principal Product | Refined wastewater |
| NAICS | 221320: Sewage Treatment Facilities |
| SIC | 4952: Sewerage Systems |
| Sales Range | $1 M to 5M |
| # of Employees | 10 |
| Plant Area |
5,000
ft2
|
| Annual Production | 1,095,000
Tgal
|
| Production Hrs. Annual | 8,760
hrs
|
| Location (State) | Texas |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $42,285 | 1,181,963 |
kWh
|
$0.036 |
| Electricity Demand | $28,986 | 2,830 |
kW-mo/yr
|
$10.24 |
| Electricity Fees | $1,489 | - |
|
- |
| TOTAL YEARLY COSTS | $72,760 | |||
| RECOMMENDED SAVINGS* | $10,130 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $3,880 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Ancillary Material Cost Savings |
|---|---|---|---|---|---|---|---|
| 01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $1,140 | $1,550 |
$790
19,836
kWh
|
$350
-
kW-mo/yr
|
- | |
| 02 | 2.4157: Establish a predictive maintenance program | $2,570 | $4,570 |
$867
21,667
kWh
|
- | $1,703 | |
| 03 | 2.3212: Optimize plant power factor | $5,800 | $11,040 | - |
$5,800
-
kW-mo/yr
|
- | |
| 04 | 2.4314: Use synthetic lubricant | $450 | $63 |
$315
7,878
kWh
|
$135
-
kW-mo/yr
|
- | |
| 05 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $170 | $47 |
$120
2,900
kWh
|
$50
-
kW-mo/yr
|
- | |
| TOTAL RECOMMENDED | $10,130 | $17,270 |
$2,092
52,281
kWh
|
$6,335
-
kW-mo/yr
|
$1,703 | ||
| TOTAL IMPLEMENTED | $3,880 | $6,167 |
$1,777
44,403
kWh
|
$400
-
kW-mo/yr
|
$1,703 | ||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs