| Assessment Year | 2023 |
|---|---|
| Principal Product | Plastic abrasives |
| NAICS | 326199: All Other Plastics Product Manufacturing |
| SIC | 3089: Plastics Products, Not Elsewhere Classified |
| Sales Range | $5 M to 10M |
| # of Employees | 22 |
| Plant Area |
58,000
ft2
|
| Annual Production | 6,000,000
lb
|
| Production Hrs. Annual | 4,172
hrs
|
| Location (State) | Texas |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $28,312 | 556,040 |
kWh
|
$0.051 |
| Electricity Demand | $27,478 | 2,812 |
kW-mo/yr
|
$9.77 |
| Electricity Fees | $6,884 | - |
|
- |
| TOTAL YEARLY COSTS | $62,674 | |||
| RECOMMENDED SAVINGS* | $27,524 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $27,524 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | One-time Revenue or Avoided Cost Savings |
|---|---|---|---|---|---|---|---|---|
| 01 | 2.8121: Apply for tax-free status for energy purchases | $23,699 | $5,000 | - | - | $4,739 | $18,960 | |
| 02 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $1,185 | $690 |
$775
14,000
kWh
|
$410
-
kW-mo/yr
|
- | - | |
| 03 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $635 | - |
$390
7,105
kWh
|
$245
-
kW-mo/yr
|
- | - | |
| 04 | 2.6218: Turn off equipment when not in use | $900 | - |
$540
9,750
kWh
|
$360
-
kW-mo/yr
|
- | - | |
| 05 | 2.7135: Install occupancy sensors | $360 | $290 |
$360
6,570
kWh
|
- | - | - | |
| 06 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $435 | $1,900 |
$290
5,230
kWh
|
$145
-
kW-mo/yr
|
- | - | |
| 07 | 2.7124: Make a practice of turning off lights when not needed | $310 | $90 |
$210
3,760
kWh
|
$100
-
kW-mo/yr
|
- | - | |
| TOTAL RECOMMENDED | $27,524 | $7,970 |
$2,565
46,415
kWh
|
$1,260
-
kW-mo/yr
|
$4,739 | $18,960 | ||
| TOTAL IMPLEMENTED | $27,524 | $7,970 |
$2,565
46,415
kWh
|
$1,260
-
kW-mo/yr
|
$4,739 | $18,960 | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | One-time Revenue or Avoided Cost Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs