Assessment Year | 2022 |
---|---|
Principal Product | Christian disciples |
NAICS | 813110: Religious Organizations |
SIC | 8661: Religious Organizations |
Sales Range | less than $500 k |
# of Employees | 8 |
Plant Area |
68,622
ft2
|
Annual Production | 120
pieces
|
Production Hrs. Annual | 2,600
hrs
|
Location (State) | Texas |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | ||
---|---|---|---|---|---|
Electricity Usage | $15,543 | 388,580 |
kWh
|
$0.040 | |
Electricity Demand | $20,120 | 1,562 |
kW-mo/yr
|
$12.88 | |
Natural Gas | $5,919 | 606 |
MMBtu
|
$9.77 | |
Waste Disposal Costs | |||||
Water Usage | $326 | 63 |
Tgal
|
$5.16 | |
TOTAL YEARLY COSTS | $41,908 | ||||
RECOMMENDED SAVINGS* | $5,625 |
See individual recommendations below
*Non-energy impacts included in savings.
|
|||
IMPLEMENTED SAVINGS* | - |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings |
---|---|---|---|---|---|---|---|
01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $4,415 | $26,260 |
$1,239
30,984
kWh
|
$3,176
-
kW-mo/yr
|
- | |
02 | 2.7135: Install occupancy sensors | $503 | $13,225 |
$503
12,574
kWh
|
- | - | |
03 | 2.4146: Use adjustable frequency drive or multiple speed motors on existing system | $487 | $4,000 |
$487
12,175
kWh
|
- | - | |
04 | 2.7261: Install timers and/or thermostats | $220 | $1,800 |
$150
3,732
kWh
|
- |
$70
-
MMBtu
|
|
TOTAL RECOMMENDED | $5,625 | $45,285 |
$2,379
59,465
kWh
|
$3,176
-
kW-mo/yr
|
$70
-
MMBtu
|
||
TOTAL IMPLEMENTED | - | - | - | - | - |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs