| Assessment Year | 2022 |
|---|---|
| Principal Product | Air conditioning equipment |
| NAICS | 333415: Air-Conditioning and Warm Air Heating Equipment and Commercial and Industrial Refrigeration Equipmen |
| SIC | 3585: Air-Conditioning and Warm Air Heating Equipment and Commercial and Industrial Refrigeration Equipment |
| Sales Range | $50 M to 100M |
| # of Employees | 170 |
| Plant Area |
125,000
ft2
|
| Annual Production | 12,173
pieces
|
| Production Hrs. Annual | 4,250
hrs
|
| Location (State) | Texas |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | ||
|---|---|---|---|---|---|
| Electricity Usage | $199,450 | 2,548,492 |
kWh
|
$0.078 | |
| Electricity Fees | $3,343 | - |
|
- | |
| Natural Gas | $5,966 | 552 |
MMBtu
|
$10.81 | |
| Waste Disposal Costs | |||||
| Water Usage | $19,643 | 1,661 |
Tgal
|
$11.83 | |
| TOTAL YEARLY COSTS | $228,402 | ||||
| RECOMMENDED SAVINGS* | $31,560 |
See individual recommendations below
*Non-energy impacts included in savings.
|
|||
| IMPLEMENTED SAVINGS* | $13,770 | ||||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings |
|---|---|---|---|---|---|---|---|
| 01 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $12,035 | $2,100 |
$8,350
107,000
kWh
|
$3,685
-
kW-mo/yr
|
- | |
| 02 | 2.6218: Turn off equipment when not in use | $9,360 | - |
$9,360
120,000
kWh
|
- | - | |
| 03 | 2.7124: Make a practice of turning off lights when not needed | $4,410 | $1,000 |
$4,410
56,530
kWh
|
- | - | |
| 04 | 2.4231: Reduce the pressure of compressed air to the minimum required | $2,745 | $2,528 |
$1,915
24,554
kWh
|
$830
-
kW-mo/yr
|
- | |
| 05 | 2.7135: Install occupancy sensors | $1,790 | $2,520 |
$1,790
22,960
kWh
|
- | - | |
| 06 | 2.4239: Eliminate or reduce compressed air usage | $675 | $1,275 |
$675
8,640
kWh
|
- | - | |
| 07 | 2.8123: Pay utility bills on time | $545 | - | - | - | $545 | |
| TOTAL RECOMMENDED | $31,560 | $9,423 |
$26,500
339,684
kWh
|
$4,515
-
kW-mo/yr
|
$545 | ||
| TOTAL IMPLEMENTED | $13,770 | $1,000 |
$13,770
176,530
kWh
|
- | - | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs