| Assessment Year | 2022 |
|---|---|
| Principal Product | Conveyors |
| NAICS | 333922: Conveyor and Conveying Equipment Manufacturing |
| SIC | 3535: Conveyors and Conveying Equipment |
| Sales Range | $10 M to 50M |
| # of Employees | 60 |
| Plant Area |
120,000
ft2
|
| Annual Production | 3,500,000
ton
|
| Production Hrs. Annual | 3,050
hrs
|
| Location (State) | Texas |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $41,311 | 760,037 |
kWh
|
$0.054 |
| Electricity Demand | $37,440 | 3,877 |
kW-mo/yr
|
$9.66 |
| Electricity Fees | $6,469 | - |
|
- |
| TOTAL YEARLY COSTS | $85,220 | |||
| RECOMMENDED SAVINGS* | $48,632 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $37,370 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | One-time Revenue or Avoided Cost Savings |
|---|---|---|---|---|---|---|---|---|
| 01 | 2.8121: Apply for tax-free status for energy purchases | $32,345 | $5,000 | - | - | $6,469 | $25,876 | |
| 02 | 2.3212: Optimize plant power factor | $7,487 | $13,455 | - |
$7,487
-
kW-mo/yr
|
- | - | |
| 03 | 2.4231: Reduce the pressure of compressed air to the minimum required | $3,775 | $2,575 |
$2,005
37,140
kWh
|
$1,770
-
kW-mo/yr
|
- | - | |
| 04 | 2.6218: Turn off equipment when not in use | $2,135 | - |
$1,130
21,010
kWh
|
$1,005
-
kW-mo/yr
|
- | - | |
| 05 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $1,650 | $1,000 |
$880
16,240
kWh
|
$770
-
kW-mo/yr
|
- | - | |
| 06 | 2.4239: Eliminate or reduce compressed air usage | $830 | $2,100 |
$830
15,340
kWh
|
- | - | - | |
| 07 | 2.7135: Install occupancy sensors | $410 | $1,085 |
$410
7,601
kWh
|
- | - | - | |
| TOTAL RECOMMENDED | $48,632 | $25,215 |
$5,255
97,331
kWh
|
$11,032
-
kW-mo/yr
|
$6,469 | $25,876 | ||
| TOTAL IMPLEMENTED | $37,370 | $9,185 |
$3,250
60,191
kWh
|
$1,775
-
kW-mo/yr
|
$6,469 | $25,876 | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | One-time Revenue or Avoided Cost Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs