| Assessment Year | 2022 |
|---|---|
| Principal Product | Carbonated beverages |
| NAICS | 312111: Soft Drink Manufacturing |
| SIC | 2086: Bottled and Canned Soft Drinks and Carbonated Waters |
| Sales Range | $10 M to 50M |
| # of Employees | 40 |
| Plant Area |
138,000
ft2
|
| Annual Production | 20,000,000
pieces
|
| Production Hrs. Annual | 5,334
hrs
|
| Location (State) | Texas |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | ||
|---|---|---|---|---|---|
| Electricity Usage | $85,745 | 1,950,449 |
kWh
|
$0.044 | |
| Electricity Demand | $68,638 | 8,060 |
kW-mo/yr
|
$8.52 | |
| Electricity Fees | $7,307 | - |
|
- | |
| Natural Gas | $31,125 | 4,298 |
MMBtu
|
$7.24 | |
| Waste Disposal Costs | |||||
| Water Usage | $134,361 | 17,352 |
Tgal
|
$7.74 | |
| TOTAL YEARLY COSTS | $327,176 | ||||
| RECOMMENDED SAVINGS* | $63,511 |
See individual recommendations below
*Non-energy impacts included in savings.
|
|||
| IMPLEMENTED SAVINGS* | $62,786 | ||||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | One-time Revenue or Avoided Cost Savings |
|---|---|---|---|---|---|---|---|---|
| 01 | 2.8121: Apply for tax-free status for energy purchases | $55,740 | $5,500 | - | - | $11,148 | $44,592 | |
| 02 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $3,340 | $1,000 |
$2,180
49,600
kWh
|
$1,160
-
kW-mo/yr
|
- | - | |
| 03 | 2.3212: Optimize plant power factor | $1,420 | $2,240 | - |
$1,420
-
kW-mo/yr
|
- | - | |
| 04 | 2.4231: Reduce the pressure of compressed air to the minimum required | $840 | $10 |
$550
12,500
kWh
|
$290
-
kW-mo/yr
|
- | - | |
| 05 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $725 | $68 |
$500
11,265
kWh
|
$225
-
kW-mo/yr
|
- | - | |
| 06 | 2.4314: Use synthetic lubricant | $506 | $220 |
$343
7,725
kWh
|
$163
-
kW-mo/yr
|
- | - | |
| 07 | 2.7135: Install occupancy sensors | $355 | $232 |
$355
8,095
kWh
|
- | - | - | |
| 08 | 2.7134: Use photocell controls | $330 | $110 |
$215
4,900
kWh
|
$115
-
kW-mo/yr
|
- | - | |
| 09 | 2.4239: Eliminate or reduce compressed air usage | $255 | $50 |
$255
5,850
kWh
|
- | - | - | |
| TOTAL RECOMMENDED | $63,511 | $9,430 |
$4,398
99,935
kWh
|
$3,373
-
kW-mo/yr
|
$11,148 | $44,592 | ||
| TOTAL IMPLEMENTED | $62,786 | $9,362 |
$3,898
88,670
kWh
|
$3,148
-
kW-mo/yr
|
$11,148 | $44,592 | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | One-time Revenue or Avoided Cost Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs