Assessment Year 2022
Principal Product Carbonated beverages
NAICS 312111: Soft Drink Manufacturing
SIC 2086: Bottled and Canned Soft Drinks and Carbonated Waters
Sales Range $10
M
to 50
M
# of Employees 40
Plant Area 138,000
ft2
Annual Production 20,000,000
pieces
Production Hrs. Annual 5,334
hrs
Location (State) Texas

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $85,745 1,950,449
kWh
Electricity Demand $68,638 8,060
kW-mo/yr
Electricity Fees $7,307 -
Natural Gas $31,125 4,298
MMBtu
Waste Disposal Costs
Water Usage $134,361 17,352
Tgal
TOTAL YEARLY COSTS $327,176
RECOMMENDED SAVINGS* $63,511 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $62,786

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings Electricity Fees Savings One-time Revenue or Avoided Cost Savings
01 2.8121: Apply for tax-free status for energy purchases $55,740 $5,500 - - $11,148 $44,592
02 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves $3,340 $1,000 $2,180
49,600
kWh
$1,160
-
kW-mo/yr
- -
03 2.3212: Optimize plant power factor $1,420 $2,240 - $1,420
-
kW-mo/yr
- -
04 2.4231: Reduce the pressure of compressed air to the minimum required $840 $10 $550
12,500
kWh
$290
-
kW-mo/yr
- -
05 2.4111: Utilize energy-efficient belts and other improved mechanisms $725 $68 $500
11,265
kWh
$225
-
kW-mo/yr
- -
06 2.4314: Use synthetic lubricant $506 $220 $343
7,725
kWh
$163
-
kW-mo/yr
- -
07 2.7135: Install occupancy sensors $355 $232 $355
8,095
kWh
- - -
08 2.7134: Use photocell controls $330 $110 $215
4,900
kWh
$115
-
kW-mo/yr
- -
09 2.4239: Eliminate or reduce compressed air usage $255 $50 $255
5,850
kWh
- - -
TOTAL RECOMMENDED $63,511 $9,430 $4,398
99,935
kWh
$3,373
-
kW-mo/yr
$11,148 $44,592
TOTAL IMPLEMENTED $62,786 $9,362 $3,898
88,670
kWh
$3,148
-
kW-mo/yr
$11,148 $44,592
Yearly Savings* Imp'd Cost* Electricity Usage Savings Electricity Demand Savings Electricity Fees Savings One-time Revenue or Avoided Cost Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs