| Assessment Year | 2022 |
|---|---|
| Principal Product | Conveyors |
| NAICS | 333922: Conveyor and Conveying Equipment Manufacturing |
| SIC | 3535: Conveyors and Conveying Equipment |
| Sales Range | $10 M to 50M |
| # of Employees | 140 |
| Plant Area |
120,000
ft2
|
| Annual Production | 200,000,000
ton
|
| Production Hrs. Annual | 2,754
hrs
|
| Location (State) | Texas |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $56,320 | 1,583,207 |
kWh
|
$0.036 |
| Electricity Demand | $72,577 | 11,090 |
kW-mo/yr
|
$6.54 |
| Electricity Fees | $4,611 | - |
|
- |
| TOTAL YEARLY COSTS | $133,508 | |||
| RECOMMENDED SAVINGS* | $43,672 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $228 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Ancillary Material Cost Savings | One-time Revenue or Avoided Cost Savings |
|---|---|---|---|---|---|---|---|---|---|
| 01 | 2.3212: Optimize plant power factor | $18,385 | $33,511 | - |
$18,385
-
kW-mo/yr
|
- | - | - | |
| 02 | 2.8114: Change rate schedules or other changes in utility service | $12,030 | $110 | - | - | - | - | $12,030 | |
| 03 | 2.8112: Combine utility meters | $7,115 | $4,500 | - |
$4,775
-
kW-mo/yr
|
$2,340 | - | - | |
| 04 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $2,975 | $3,000 |
$1,425
40,720
kWh
|
$1,550
-
kW-mo/yr
|
- | - | - | |
| 05 | 2.8117: Install sub-metering equipment | $2,741 | $500 |
$2,741
78,304
kWh
|
- | - | - | - | |
| 06 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $228 | $1,190 |
$130
3,640
kWh
|
$100
-
kW-mo/yr
|
- | $(-2.0) | - | |
| 07 | 2.7135: Install occupancy sensors | $18 | $84 |
$18
505
kWh
|
- | - | - | - | |
| 08 | 2.6212: Turn off equipment during breaks, reduce operating time | $180 | $160 |
$180
5,145
kWh
|
- | - | - | - | |
| TOTAL RECOMMENDED | $43,672 | $43,055 |
$4,494
128,314
kWh
|
$24,810
-
kW-mo/yr
|
$2,340 | $(-2.0) | $12,030 | ||
| TOTAL IMPLEMENTED | $228 | $1,190 |
$130
3,640
kWh
|
$100
-
kW-mo/yr
|
- | $(-2.0) | - | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Ancillary Material Cost Savings | One-time Revenue or Avoided Cost Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs