| Assessment Year | 2022 |
|---|---|
| Principal Product | Fungicides |
| NAICS | 325320: Pesticide and Other Agricultural Chemical Manufacturing |
| SIC | 2879: Pesticides and Agricultural Chemicals, Not Elsewhere Classified |
| Sales Range | $50 M to 100M |
| # of Employees | 53 |
| Plant Area |
72,670
ft2
|
| Annual Production | 15,000,000
lb
|
| Production Hrs. Annual | 8,496
hrs
|
| Location (State) | Texas |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $219,010 | 5,043,700 |
kWh
|
$0.043 |
| Electricity Demand | $75,270 | 11,400 |
kW-mo/yr
|
$6.60 |
| Electricity Fees | $33,814 | - |
|
- |
| Natural Gas | $117,056 | 42,698 |
MMBtu
|
$2.74 |
| TOTAL YEARLY COSTS | $445,150 | |||
| RECOMMENDED SAVINGS* | $156,030 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $156,030 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Ancillary Material Cost Savings | One-time Revenue or Avoided Cost Savings |
|---|---|---|---|---|---|---|---|---|---|
| 01 | 2.8121: Apply for tax-free status for energy purchases | $123,505 | $10,000 | - | - | $24,701 | - | $98,804 | |
| 02 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $12,090 | $5,000 |
$9,520
237,900
kWh
|
$2,570
-
kW-mo/yr
|
- | - | - | |
| 03 | 2.4133: Use most efficient type of electric motors | $2,070 | $10,152 |
$1,630
40,741
kWh
|
$440
-
kW-mo/yr
|
- | - | - | |
| 04 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $12,720 | $29,570 |
$9,140
228,510
kWh
|
$2,480
-
kW-mo/yr
|
- | $1,100 | - | |
| 05 | 2.4314: Use synthetic lubricant | $1,646 | $300 |
$1,296
32,394
kWh
|
$350
-
kW-mo/yr
|
- | - | - | |
| 06 | 2.7111: Reduce illumination to minimum necessary levels | $2,835 | $1,420 |
$1,850
46,270
kWh
|
$985
-
kW-mo/yr
|
- | - | - | |
| 07 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $1,164 | - |
$917
22,924
kWh
|
$247
-
kW-mo/yr
|
- | - | - | |
| TOTAL RECOMMENDED | $156,030 | $56,442 |
$24,353
608,739
kWh
|
$7,072
-
kW-mo/yr
|
$24,701 | $1,100 | $98,804 | ||
| TOTAL IMPLEMENTED | $156,030 | $56,442 |
$24,353
608,739
kWh
|
$7,072
-
kW-mo/yr
|
$24,701 | $1,100 | $98,804 | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Ancillary Material Cost Savings | One-time Revenue or Avoided Cost Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs