Assessment Year | 2021 |
---|---|
Principal Product | gaskets, bolts and hose assemblies |
NAICS | 339991: Gasket, Packing, and Sealing Device Manufacturing |
SIC | 3053: Gaskets, Packing, and Sealing Devices |
Sales Range | $100 M to 500M |
# of Employees | 250 |
Plant Area |
130,000
ft2
|
Annual Production | 4,000,000
pieces
|
Production Hrs. Annual | 6,000
hrs
|
Location (State) | Texas |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $262,866 | 5,086,728 |
kWh
|
$0.052 |
Electricity Demand | $109,836 | 11,559 |
kW-mo/yr
|
$9.50 |
Electricity Fees | $11,460 | - |
|
- |
Natural Gas | $18,258 | 2,280 |
MMBtu
|
$8.01 |
TOTAL YEARLY COSTS | $402,420 | |||
RECOMMENDED SAVINGS* | $26,546 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $26,546 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings |
---|---|---|---|---|---|---|---|
01 | 2.3212: Optimize plant power factor | $13,390 | $30,920 | - |
$13,390
-
kW-mo/yr
|
- | |
02 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $7,760 | $1,300 |
$6,060
131,700
kWh
|
$1,700
-
kW-mo/yr
|
- | |
03 | 2.7124: Make a practice of turning off lights when not needed | $3,630 | - |
$3,630
78,860
kWh
|
- | - | |
04 | 2.8123: Pay utility bills on time | $1,766 | - | - | - | $1,766 | |
TOTAL RECOMMENDED | $26,546 | $32,220 |
$9,690
210,560
kWh
|
$15,090
-
kW-mo/yr
|
$1,766 | ||
TOTAL IMPLEMENTED | $26,546 | $32,220 |
$9,690
210,560
kWh
|
$15,090
-
kW-mo/yr
|
$1,766 |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs