| Assessment Year | 2021 |
|---|---|
| Principal Product | Oil & Gas process equipment |
| NAICS | 333132: Oil and Gas Field Machinery and Equipment Manufacturing |
| SIC | 3533: Oil and Gas Field Machinery and Equipment |
| Sales Range | $10 M to 50M |
| # of Employees | 85 |
| Plant Area |
155,000
ft2
|
| Annual Production | 400
pieces
|
| Production Hrs. Annual | 4,160
hrs
|
| Location (State) | Texas |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | ||
|---|---|---|---|---|---|
| Electricity Usage | $59,593 | 1,217,520 |
kWh
|
$0.049 | |
| Electricity Demand | $72,248 | 8,121 |
kW-mo/yr
|
$8.90 | |
| Electricity Fees | $797 | - |
|
- | |
| Natural Gas | $31,348 | 4,609 |
MMBtu
|
$6.80 | |
| Waste Disposal Costs | |||||
| Water Usage | $9,088 | 1,118 |
Tgal
|
$8.13 | |
| TOTAL YEARLY COSTS | $173,074 | ||||
| RECOMMENDED SAVINGS* | $53,505 |
See individual recommendations below
*Non-energy impacts included in savings.
|
|||
| IMPLEMENTED SAVINGS* | - | ||||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Personnel Changes Savings | Ancillary Material Cost Savings |
|---|---|---|---|---|---|---|---|---|---|
| 01 | 2.4146: Use adjustable frequency drive or multiple speed motors on existing system | $8,600 | $3,400 |
$3,700
87,000
kWh
|
$4,900
-
kW-mo/yr
|
- | - | - | |
| 02 | 2.8121: Apply for tax-free status for energy purchases | $10,940 | $15,000 | - | - | $10,940 | - | - | |
| 03 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $6,370 | $30,000 |
$2,600
66,000
kWh
|
$1,300
-
kW-mo/yr
|
- | $2,800 | $(-330.0) | |
| 04 | 2.3212: Optimize plant power factor | $21,250 | $22,150 | - |
$21,250
-
kW-mo/yr
|
- | - | - | |
| 05 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $1,070 | $2,117 |
$400
9,350
kWh
|
$600
-
kW-mo/yr
|
- | - | $70 | |
| 06 | 2.7124: Make a practice of turning off lights when not needed | $75 | $152 |
$30
720
kWh
|
$45
-
kW-mo/yr
|
- | - | - | |
| 07 | 2.6218: Turn off equipment when not in use | $5,200 | $1,350 |
$5,200
123,700
kWh
|
- | - | - | - | |
| TOTAL RECOMMENDED | $53,505 | $74,169 |
$11,930
286,770
kWh
|
$28,095
-
kW-mo/yr
|
$10,940 | $2,800 | $(-260.0) | ||
| TOTAL IMPLEMENTED | - | - | - | - | - | - | - | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Personnel Changes Savings | Ancillary Material Cost Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs