| Assessment Year | 2019 |
|---|---|
| Principal Product | wastewater treatment plant |
| NAICS | 221320: Sewage Treatment Facilities |
| SIC | 4952: Sewerage Systems |
| Sales Range | less than $500 k |
| # of Employees | 3 |
| Plant Area |
3,000
ft2
|
| Annual Production | 547,500
Tgal
|
| Production Hrs. Annual | 8,736
hrs
|
| Location (State) | Texas |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $42,513 | 825,564 |
kWh
|
$0.051 |
| Electricity Demand | $14,645 | 1,601 |
kW-mo/yr
|
$9.15 |
| Electricity Fees | $1,877 | - |
|
- |
| TOTAL YEARLY COSTS | $59,035 | |||
| RECOMMENDED SAVINGS* | $20,541 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $20,541 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings |
|---|---|---|---|---|---|---|
| 01 | 3.1191: Change procedures / equipment / operating conditions | $13,870 | $29,400 |
$11,200
224,000
kWh
|
$2,670
-
kW-mo/yr
|
|
| 02 | 2.3212: Optimize plant power factor | $4,100 | $5,300 | - |
$4,100
-
kW-mo/yr
|
|
| 03 | 2.4146: Use adjustable frequency drive or multiple speed motors on existing system | $1,921 | $12,100 |
$1,921
38,418
kWh
|
- | |
| 04 | 2.4314: Use synthetic lubricant | $415 | $510 |
$282
5,646
kWh
|
$133
-
kW-mo/yr
|
|
| 05 | 2.7134: Use photocell controls | $235 | $17 |
$160
3,180
kWh
|
$75
-
kW-mo/yr
|
|
| TOTAL RECOMMENDED | $20,541 | $47,327 |
$13,563
271,244
kWh
|
$6,978
-
kW-mo/yr
|
||
| TOTAL IMPLEMENTED | $20,541 | $47,327 |
$13,563
271,244
kWh
|
$6,978
-
kW-mo/yr
|
||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs