Assessment Year | 2019 |
---|---|
Principal Product | Thermoplastic extruded stock rods, plates, and tubes. Injection molded |
NAICS | 326121: Unlaminated Plastics Profile Shape Manufacturing |
SIC | 2821: Plastics Materials, Synthetic Resins, and Nonvulcanizable Elastomers |
Sales Range | $10 M to 50M |
# of Employees | 50 |
Plant Area |
64,000
ft2
|
Annual Production | 60,000
lb
|
Production Hrs. Annual | 5,976
hrs
|
Location (State) | Texas |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $77,835 | 1,743,360 |
kWh
|
$0.045 |
Electricity Demand | $30,333 | 4,802 |
kW-mo/yr
|
$6.32 |
Electricity Fees | $253 | - |
|
- |
TOTAL YEARLY COSTS | $108,421 | |||
RECOMMENDED SAVINGS* | $16,363 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $5,155 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Personnel Changes Savings | Ancillary Material Cost Savings |
---|---|---|---|---|---|---|---|---|
01 | 2.4231: Reduce the pressure of compressed air to the minimum required | $4,349 | $43 |
$3,378
76,775
kWh
|
$971
-
kW-mo/yr
|
- | - | |
02 | 2.3212: Optimize plant power factor | $6,054 | $17,860 | - |
$6,054
-
kW-mo/yr
|
- | - | |
03 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $4,710 | $7,720 |
$3,660
83,186
kWh
|
$1,050
-
kW-mo/yr
|
- | - | |
04 | 2.7111: Reduce illumination to minimum necessary levels | $805 | $762 |
$412
9,358
kWh
|
$120
-
kW-mo/yr
|
$113 | $160 | |
05 | 2.4239: Eliminate or reduce compressed air usage | $445 | $780 |
$445
10,113
kWh
|
- | - | - | |
TOTAL RECOMMENDED | $16,363 | $27,165 |
$7,895
179,432
kWh
|
$8,195
-
kW-mo/yr
|
$113 | $160 | ||
TOTAL IMPLEMENTED | $5,155 | $8,500 |
$4,105
93,299
kWh
|
$1,050
-
kW-mo/yr
|
- | - |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs