Assessment Year | 2019 |
---|---|
Principal Product | Mechanical seals |
NAICS | 339991: Gasket, Packing, and Sealing Device Manufacturing |
SIC | 3053: Gaskets, Packing, and Sealing Devices |
Sales Range | $50 M to 100M |
# of Employees | 110 |
Plant Area |
65,000
ft2
|
Annual Production | 8,750
pieces
|
Production Hrs. Annual | 5,024
hrs
|
Location (State) | Texas |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $53,753 | 1,159,680 |
kWh
|
$0.046 |
Electricity Demand | $24,785 | 3,910 |
kW-mo/yr
|
$6.34 |
Electricity Fees | $4,804 | - |
|
- |
TOTAL YEARLY COSTS | $83,342 | |||
RECOMMENDED SAVINGS* | $29,000 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $22,400 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | One-time Revenue or Avoided Cost Savings |
---|---|---|---|---|---|---|---|---|
01 | 2.3212: Optimize plant power factor | $4,880 | $12,230 | - |
$4,880
-
kW-mo/yr
|
- | - | |
02 | 2.8121: Apply for tax-free status for energy purchases | $22,150 | $3,000 | - | - | $4,430 | $17,720 | |
03 | 2.4231: Reduce the pressure of compressed air to the minimum required | $1,340 | $1,800 |
$1,340
29,800
kWh
|
- | - | - | |
04 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $140 | $300 |
$140
3,085
kWh
|
- | - | - | |
05 | 2.7135: Install occupancy sensors | $110 | $200 |
$110
2,500
kWh
|
- | - | - | |
06 | 2.4231: Reduce the pressure of compressed air to the minimum required | $380 | $20 |
$250
5,700
kWh
|
$130
-
kW-mo/yr
|
- | - | |
TOTAL RECOMMENDED | $29,000 | $17,550 |
$1,840
41,085
kWh
|
$5,010
-
kW-mo/yr
|
$4,430 | $17,720 | ||
TOTAL IMPLEMENTED | $22,400 | $3,500 |
$250
5,585
kWh
|
- | $4,430 | $17,720 | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | One-time Revenue or Avoided Cost Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs