Assessment Year | 2017 |
---|---|
Principal Product | Processed lumber |
NAICS | 321113: Sawmills |
SIC | 2421: Sawmills and Planing Mills, General |
Sales Range | $50 M to 100M |
# of Employees | 68 |
Plant Area |
100,000
ft2
|
Annual Production | 30,000
thousand feet
|
Production Hrs. Annual | 2,636
hrs
|
Location (State) | Texas |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $119,669 | 2,413,330 |
kWh
|
$0.050 |
Electricity Demand | $83,299 | 10,070 |
kW-mo/yr
|
$8.27 |
Electricity Fees | $315 | - |
|
- |
Natural Gas | $67,274 | 15,918 |
MMBtu
|
$4.23 |
TOTAL YEARLY COSTS | $270,557 | |||
RECOMMENDED SAVINGS* | $81,990 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $62,220 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings |
---|---|---|---|---|---|---|
01 | 2.4239: Eliminate or reduce compressed air usage | $44,300 | $31,800 |
$18,200
364,800
kWh
|
$26,100
-
kW-mo/yr
|
|
02 | 2.3212: Optimize plant power factor | $17,900 | $28,900 | - |
$17,900
-
kW-mo/yr
|
|
03 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $7,430 | - |
$3,310
66,200
kWh
|
$4,120
-
kW-mo/yr
|
|
04 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $6,820 | $9,600 |
$3,480
69,600
kWh
|
$3,340
-
kW-mo/yr
|
|
05 | 2.4314: Use synthetic lubricant | $2,400 | - |
$1,200
23,800
kWh
|
$1,200
-
kW-mo/yr
|
|
06 | 2.6218: Turn off equipment when not in use | $1,870 | - |
$1,870
37,300
kWh
|
- | |
07 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $730 | $300 |
$370
7,420
kWh
|
$360
-
kW-mo/yr
|
|
08 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $540 | $300 |
$275
5,500
kWh
|
$265
-
kW-mo/yr
|
|
TOTAL RECOMMENDED | $81,990 | $70,900 |
$28,705
574,620
kWh
|
$53,285
-
kW-mo/yr
|
||
TOTAL IMPLEMENTED | $62,220 | $42,000 |
$26,835
537,320
kWh
|
$35,385
-
kW-mo/yr
|
||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs