Assessment Year | 2017 |
---|---|
Principal Product | Custom molded plastics |
NAICS | 326199: All Other Plastics Product Manufacturing |
SIC | 3089: Plastics Products, Not Elsewhere Classified |
Sales Range | $5 M to 10M |
# of Employees | 35 |
Plant Area |
40,000
ft2
|
Annual Production | 1,500,000
units
|
Production Hrs. Annual | 6,048
hrs
|
Location (State) | Texas |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $62,400 | 638,000 |
kWh
|
$0.098 |
Electricity Demand | $4,130 | 2,060 |
kW-mo/yr
|
$2.00 |
Natural Gas | $60,000 | 9,193 |
MMBtu
|
$6.53 |
TOTAL YEARLY COSTS | $126,530 | |||
RECOMMENDED SAVINGS* | $21,027 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $17,497 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Administrative Changes Savings |
---|---|---|---|---|---|---|---|
01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $7,040 | $14,990 |
$6,760
69,700
kWh
|
$280
-
kW-mo/yr
|
- | |
02 | 2.4146: Use adjustable frequency drive or multiple speed motors on existing system | $3,030 | $9,000 |
$3,030
31,230
kWh
|
- | - | |
03 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $2,590 | $6,390 |
$2,460
25,400
kWh
|
$130
-
kW-mo/yr
|
- | |
04 | 2.7135: Install occupancy sensors | $1,710 | $400 |
$1,710
17,600
kWh
|
- | - | |
05 | 2.8123: Pay utility bills on time | $1,617 | - | - | - | $1,617 | |
06 | 2.4239: Eliminate or reduce compressed air usage | $1,600 | $300 |
$1,600
16,510
kWh
|
- | - | |
07 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $1,550 | $2,000 |
$1,490
15,410
kWh
|
$60
-
kW-mo/yr
|
- | |
08 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $1,390 | $390 |
$260
2,730
kWh
|
$10
-
kW-mo/yr
|
$1,120 | |
09 | 2.4231: Reduce the pressure of compressed air to the minimum required | $500 | $20 |
$480
4,990
kWh
|
$20
-
kW-mo/yr
|
- | |
TOTAL RECOMMENDED | $21,027 | $33,490 |
$17,790
183,570
kWh
|
$500
-
kW-mo/yr
|
$2,737 | ||
TOTAL IMPLEMENTED | $17,497 | $24,470 |
$14,280
147,350
kWh
|
$480
-
kW-mo/yr
|
$2,737 | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Administrative Changes Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs