ITAC Assessment: AM0728
ITAC logo
ITAC Assessment: AM0728
Grant Funding Opportunity NOW OPEN
Up to $300k at 50% cost share for qualifying* projects.
Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received an ITAC, Onsite Energy/CHP TAP, or qualified equivalent assessment since 2018 can now apply for grants for implementation of assessment recommendations at up to 50% of qualifying* project costs with a maximum of $300,000 per grant.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
Assessment Year 2017
Principal Product Pressure treated lumber
NAICS 321114: Wood Preservation
SIC 2491: Wood Preserving
Sales Range $10
M
to 50
M
# of Employees 55
Plant Area 123,000
ft2
Annual Production 240,000
thousand feet
Production Hrs. Annual 6,048
hrs
Location (State) Texas

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $74,295 1,236,964
kWh
Electricity Demand $59,269 3,922
kW-mo/yr
Electricity Fees $10,427 -
Natural Gas $13,688 1,730
MMBtu
TOTAL YEARLY COSTS $157,679
RECOMMENDED SAVINGS* $95,852 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $95,852

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings Electricity Fees Savings Administrative Changes Savings One-time Revenue or Avoided Cost Savings
01 2.7142: Utilize higher efficiency lamps and/or ballasts $14,680 $20,300 $9,740
159,700
kWh
$4,940
-
kW-mo/yr
- - -
02 2.3212: Optimize plant power factor $8,480 $5,420 - $8,480
-
kW-mo/yr
- - -
03 2.8121: Apply for tax-free status for energy purchases $41,700 $4,000 - - $8,340 - $33,360
04 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves $6,530 $1,000 $4,330
71,000
kWh
$2,200
-
kW-mo/yr
- - -
05 2.7134: Use photocell controls $2,740 $140 $2,740
45,000
kWh
- - - -
06 2.7121: Utilize daylight whenever possible in lieu of artificial light $2,100 $1,070 $2,100
34,800
kWh
- - - -
07 2.8121: Apply for tax-free status for energy purchases $7,250 $1,000 - - - $1,450 $5,800
08 2.4157: Establish a predictive maintenance program $11,310 $4,370 $385
6,293
kWh
$485
-
kW-mo/yr
- $10,440 -
09 2.8123: Pay utility bills on time $676 - - - $676 - -
10 2.4314: Use synthetic lubricant $386 - $188
3,090
kWh
$198
-
kW-mo/yr
- - -
TOTAL RECOMMENDED $95,852 $37,300 $19,483
319,883
kWh
$16,303
-
kW-mo/yr
$9,016 $11,890 $39,160
TOTAL IMPLEMENTED $95,852 $37,300 $19,483
319,883
kWh
$16,303
-
kW-mo/yr
$9,016 $11,890 $39,160
Yearly Savings* Imp'd Cost* Electricity Usage Savings Electricity Demand Savings Electricity Fees Savings Administrative Changes Savings One-time Revenue or Avoided Cost Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs