Assessment Year | 2016 |
---|---|
Principal Product | Corrugated expansion joints for pressure piping applications |
NAICS | 332991: Ball and Roller Bearing Manufacturing |
SIC | 3499: Fabricated Metal Products, Not Elsewhere Classified |
Sales Range | $50 M to 100M |
# of Employees | 200 |
Plant Area |
88,618
ft2
|
Annual Production | 3,338
ton
|
Production Hrs. Annual | 4,500
hrs
|
Location (State) | Texas |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | ||
---|---|---|---|---|---|
Electricity Usage | $78,983 | 1,544,480 |
kWh
|
$0.051 | |
Electricity Demand | $28,149 | 4,959 |
kW-mo/yr
|
$5.68 | |
Electricity Fees | $4,886 | - |
|
- | |
Natural Gas | $24,323 | 4,030 |
MMBtu
|
$6.04 | |
Waste Disposal Costs | |||||
Water Usage | $7,824 | 981 |
Tgal
|
$7.98 | |
TOTAL YEARLY COSTS | $144,165 | ||||
RECOMMENDED SAVINGS* | $21,932 |
See individual recommendations below
*Non-energy impacts included in savings.
|
|||
IMPLEMENTED SAVINGS* | $16,272 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Administrative Changes Savings | Ancillary Material Cost Savings |
---|---|---|---|---|---|---|---|---|---|
01 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $6,440 | $2,000 |
$4,950
97,090
kWh
|
$1,490
-
kW-mo/yr
|
- | - | - | |
02 | 2.6212: Turn off equipment during breaks, reduce operating time | $4,960 | - |
$4,960
97,230
kWh
|
- | - | - | - | |
03 | 2.7291: Reschedule and rearrange multiple-source heating systems | $4,710 | $360 | - | - |
$4,710
-
MMBtu
|
- | - | |
04 | 2.4231: Reduce the pressure of compressed air to the minimum required | $3,240 | $2,410 |
$2,490
48,790
kWh
|
$750
-
kW-mo/yr
|
- | - | - | |
05 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $1,632 | $670 |
$150
2,860
kWh
|
$22
-
kW-mo/yr
|
- | $990 | $470 | |
06 | 2.7135: Install occupancy sensors | $530 | $360 |
$530
10,370
kWh
|
- | - | - | - | |
07 | 2.4314: Use synthetic lubricant | $420 | - |
$200
3,970
kWh
|
$220
-
kW-mo/yr
|
- | - | - | |
TOTAL RECOMMENDED | $21,932 | $5,800 |
$13,280
260,310
kWh
|
$2,482
-
kW-mo/yr
|
$4,710
-
MMBtu
|
$990 | $470 | ||
TOTAL IMPLEMENTED | $16,272 | $5,080 |
$12,550
245,970
kWh
|
$2,262
-
kW-mo/yr
|
- | $990 | $470 | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Administrative Changes Savings | Ancillary Material Cost Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs