ITAC Assessment: AM0719
ITAC logo
ITAC Assessment: AM0719
Grant Funding Opportunity NOW OPEN
Up to $300k at 50% cost share for qualifying* projects.
Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received an ITAC, Onsite Energy/CHP TAP, or qualified equivalent assessment since 2018 can now apply for grants for implementation of assessment recommendations at up to 50% of qualifying* project costs with a maximum of $300,000 per grant.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
Assessment Year 2016
Principal Product Plastic laminated wall systems and institutional furniture
NAICS 337127: Institutional Furniture Manufacturing
SIC 2542: Office and Store Fixtures, Partitions, Shelving, and Lockers, Except Wood
Sales Range $10
M
to 50
M
# of Employees 150
Plant Area 160,000
ft2
Annual Production 150,000
pieces
Production Hrs. Annual 3,392
hrs
Location (State) Texas

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $78,815 1,907,800
kWh
Electricity Demand $61,309 6,788
kW-mo/yr
Electricity Fees $5,209 -
TOTAL YEARLY COSTS $145,333
RECOMMENDED SAVINGS* $32,760 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $32,510

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings Electricity Fees Savings One-time Revenue or Avoided Cost Savings
01 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves $12,350 $1,000 $7,480
178,000
kWh
$4,870
-
kW-mo/yr
- -
02 2.7142: Utilize higher efficiency lamps and/or ballasts $10,680 $41,400 $6,470
154,000
kWh
$4,210
-
kW-mo/yr
- -
03 2.7142: Utilize higher efficiency lamps and/or ballasts $3,110 $6,410 $2,040
48,600
kWh
$1,070
-
kW-mo/yr
- -
04 2.8121: Apply for tax-free status for energy purchases $4,440 $2,000 - - $2,220 $2,220
05 2.4231: Reduce the pressure of compressed air to the minimum required $840 $10 $380
9,000
kWh
$460
-
kW-mo/yr
- -
06 2.4239: Eliminate or reduce compressed air usage $700 $760 $700
16,640
kWh
- - -
07 2.7123: Keep lamps and reflectors clean $390 $57 $260
6,200
kWh
$130
-
kW-mo/yr
- -
08 2.7124: Make a practice of turning off lights when not needed $250 - $250
5,990
kWh
- - -
TOTAL RECOMMENDED $32,760 $51,637 $17,580
418,430
kWh
$10,740
-
kW-mo/yr
$2,220 $2,220
TOTAL IMPLEMENTED $32,510 $51,637 $17,330
412,440
kWh
$10,740
-
kW-mo/yr
$2,220 $2,220
Yearly Savings* Imp'd Cost* Electricity Usage Savings Electricity Demand Savings Electricity Fees Savings One-time Revenue or Avoided Cost Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs