Assessment Year | 2016 |
---|---|
Principal Product | Ferrous and non-ferrous casting |
NAICS | 331512: Steel Investment Foundries |
SIC | 3324: Steel Investment Foundries |
Sales Range | $5 M to 10M |
# of Employees | 50 |
Plant Area |
30,000
ft2
|
Annual Production | 624,000
lb
|
Production Hrs. Annual | 1,600
hrs
|
Location (State) | Texas |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $117,438 | 1,468,571 |
kWh
|
$0.080 |
Electricity Demand | $28,036 | 8,092 |
kW-mo/yr
|
$3.46 |
Electricity Fees | $12,143 | - |
|
- |
Natural Gas | $54,568 | 9,854 |
MMBtu
|
$5.54 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $59,181 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $58,300 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | One-time Revenue or Avoided Cost Savings |
---|---|---|---|---|---|---|---|---|
01 | 2.8121: Apply for tax-free status for energy purchases | $49,370 | $11,000 | - | - | $9,870 | $39,500 | |
02 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $4,170 | $2,000 |
$3,120
41,400
kWh
|
$1,050
-
kW-mo/yr
|
- | - | |
03 | 2.8114: Change rate schedules or other changes in utility service | $3,110 | - |
$(-1,282.0)
-
kWh
|
$3,042
-
kW-mo/yr
|
$1,350 | - | |
04 | 2.7224: Reduce space conditioning during non-working hours | $1,650 | $80 |
$1,650
21,860
kWh
|
- | - | - | |
05 | 2.4231: Reduce the pressure of compressed air to the minimum required | $468 | $80 |
$350
4,640
kWh
|
$118
-
kW-mo/yr
|
- | - | |
06 | 2.4322: Use or replace with energy efficient substitutes | $310 | $540 |
$310
4,080
kWh
|
- | - | - | |
07 | 2.4314: Use synthetic lubricant | $103 | - |
$69
910
kWh
|
$34
-
kW-mo/yr
|
- | - | |
TOTAL RECOMMENDED | $59,181 | $13,700 |
$4,217
72,890
kWh
|
$4,244
-
kW-mo/yr
|
$11,220 | $39,500 | ||
TOTAL IMPLEMENTED | $58,300 | $13,080 |
$3,488
63,260
kWh
|
$4,092
-
kW-mo/yr
|
$11,220 | $39,500 | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | One-time Revenue or Avoided Cost Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs