ITAC Assessment: AM0702
ITAC logo
ITAC Assessment: AM0702
Grant Funding Opportunity NOW OPEN
Up to $300k at 50% cost share for qualifying* projects.
Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received an ITAC, Onsite Energy/CHP TAP, or qualified equivalent assessment since 2018 can now apply for grants for implementation of assessment recommendations at up to 50% of qualifying* project costs with a maximum of $300,000 per grant.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
Assessment Year 2016
Principal Product Folding cartons
NAICS 322212: Folding Paperboard Box Manufacturing
SIC 2657: Folding Paperboard Boxes, Including Sanitary
Sales Range $10
M
to 50
M
# of Employees 85
Plant Area 80,000
ft2
Annual Production 6,000
ton
Production Hrs. Annual 5,472
hrs
Location (State) Texas

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $125,277 1,725,624
kWh
Electricity Demand $97,206 6,960
kW-mo/yr
Electricity Fees $4,589 -
Natural Gas $3,474 404
MMBtu
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $13,732 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $12,307

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings Electricity Fees Savings Natural Gas Savings One-time Revenue or Avoided Cost Savings
01 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves $5,870 $1,320 $4,260
92,600
kWh
$1,610
-
kW-mo/yr
- - -
02 2.8123: Pay utility bills on time $2,133 - - - $2,133 - -
03 2.4231: Reduce the pressure of compressed air to the minimum required $1,090 $7 $790
17,200
kWh
$300
-
kW-mo/yr
- - -
04 2.6218: Turn off equipment when not in use $960 - $960
20,860
kWh
- - - -
05 2.4111: Utilize energy-efficient belts and other improved mechanisms $790 - $520
11,310
kWh
$270
-
kW-mo/yr
- - -
06 2.3131: Reschedule plant operations or reduce load to avoid peaks $760 - - $760
-
kW-mo/yr
- - -
07 2.7135: Install occupancy sensors $510 $380 $510
11,060
kWh
- - - -
08 2.8121: Apply for tax-free status for energy purchases $1,323 $600 - - - $265
-
MMBtu
$1,058
09 2.7228: Avoid introducing hot, humid, or dirty air into hvac system $155 $152 $87
1,900
kWh
$68
-
kW-mo/yr
- - -
10 2.7232: Replace existing hvac unit with high efficiency model $141 $350 $86
1,870
kWh
$55
-
kW-mo/yr
- - -
TOTAL RECOMMENDED $13,732 $2,809 $7,213
156,800
kWh
$3,063
-
kW-mo/yr
$2,133 $265
-
MMBtu
$1,058
TOTAL IMPLEMENTED $12,307 $2,277 $6,616
143,840
kWh
$2,235
-
kW-mo/yr
$2,133 $265
-
MMBtu
$1,058
Yearly Savings* Imp'd Cost* Electricity Usage Savings Electricity Demand Savings Electricity Fees Savings Natural Gas Savings One-time Revenue or Avoided Cost Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs