Assessment Year 2016
Principal Product Doors
NAICS 321911: Wood Window and Door Manufacturing
SIC 2431: Millwork
Sales Range $50
M
to 100
M
# of Employees 225
Plant Area 210,000
ft2
Annual Production 252,000
pieces
Production Hrs. Annual 2,268
hrs
Location (State) Texas

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $75,910 1,459,800
kWh
Electricity Demand $47,712 5,783
kW-mo/yr
Electricity Fees $13,149 -
Natural Gas $28,754 3,669
MMBtu
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $98,215 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $86,765

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings Electricity Fees Savings Personnel Changes Savings Ancillary Material Cost Savings One-time Revenue or Avoided Cost Savings
01 2.8121: Apply for tax-free status for energy purchases $52,850 $5,000 - - $10,570 - - $42,280
02 2.8121: Apply for tax-free status for energy purchases $10,955 $2,000 - - - - $2,190 $8,765
03 2.3212: Optimize plant power factor $11,450 $14,260 - $11,450
-
kW-mo/yr
- - - -
04 2.7142: Utilize higher efficiency lamps and/or ballasts $17,735 $72,050 $9,725
185,600
kWh
$8,010
-
kW-mo/yr
- - - -
05 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves $2,830 $1,400 $1,550
29,600
kWh
$1,280
-
kW-mo/yr
- - - -
06 2.7142: Utilize higher efficiency lamps and/or ballasts $1,200 $405 $300
5,700
kWh
$60
-
kW-mo/yr
- $840 - -
07 2.4322: Use or replace with energy efficient substitutes $370 $440 $370
7,100
kWh
- - - - -
08 2.4231: Reduce the pressure of compressed air to the minimum required $505 $10 $275
5,280
kWh
$230
-
kW-mo/yr
- - - -
09 2.7124: Make a practice of turning off lights when not needed $320 - $320
6,100
kWh
- - - - -
TOTAL RECOMMENDED $98,215 $95,565 $12,540
239,380
kWh
$21,030
-
kW-mo/yr
$10,570 $840 $2,190 $51,045
TOTAL IMPLEMENTED $86,765 $81,305 $12,540
239,380
kWh
$9,580
-
kW-mo/yr
$10,570 $840 $2,190 $51,045
Yearly Savings* Imp'd Cost* Electricity Usage Savings Electricity Demand Savings Electricity Fees Savings Personnel Changes Savings Ancillary Material Cost Savings One-time Revenue or Avoided Cost Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs