Assessment Year | 2016 |
---|---|
Principal Product | Doors |
NAICS | 321911: Wood Window and Door Manufacturing |
SIC | 2431: Millwork |
Sales Range | $50 M to 100M |
# of Employees | 225 |
Plant Area |
210,000
ft2
|
Annual Production | 252,000
pieces
|
Production Hrs. Annual | 2,268
hrs
|
Location (State) | Texas |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $75,910 | 1,459,800 |
kWh
|
$0.052 |
Electricity Demand | $47,712 | 5,783 |
kW-mo/yr
|
$8.25 |
Electricity Fees | $13,149 | - |
|
- |
Natural Gas | $28,754 | 3,669 |
MMBtu
|
$7.84 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $98,215 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $86,765 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Personnel Changes Savings | Ancillary Material Cost Savings | One-time Revenue or Avoided Cost Savings |
---|---|---|---|---|---|---|---|---|---|---|
01 | 2.8121: Apply for tax-free status for energy purchases | $52,850 | $5,000 | - | - | $10,570 | - | - | $42,280 | |
02 | 2.8121: Apply for tax-free status for energy purchases | $10,955 | $2,000 | - | - | - | - | $2,190 | $8,765 | |
03 | 2.3212: Optimize plant power factor | $11,450 | $14,260 | - |
$11,450
-
kW-mo/yr
|
- | - | - | - | |
04 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $17,735 | $72,050 |
$9,725
185,600
kWh
|
$8,010
-
kW-mo/yr
|
- | - | - | - | |
05 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $2,830 | $1,400 |
$1,550
29,600
kWh
|
$1,280
-
kW-mo/yr
|
- | - | - | - | |
06 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $1,200 | $405 |
$300
5,700
kWh
|
$60
-
kW-mo/yr
|
- | $840 | - | - | |
07 | 2.4322: Use or replace with energy efficient substitutes | $370 | $440 |
$370
7,100
kWh
|
- | - | - | - | - | |
08 | 2.4231: Reduce the pressure of compressed air to the minimum required | $505 | $10 |
$275
5,280
kWh
|
$230
-
kW-mo/yr
|
- | - | - | - | |
09 | 2.7124: Make a practice of turning off lights when not needed | $320 | - |
$320
6,100
kWh
|
- | - | - | - | - | |
TOTAL RECOMMENDED | $98,215 | $95,565 |
$12,540
239,380
kWh
|
$21,030
-
kW-mo/yr
|
$10,570 | $840 | $2,190 | $51,045 | ||
TOTAL IMPLEMENTED | $86,765 | $81,305 |
$12,540
239,380
kWh
|
$9,580
-
kW-mo/yr
|
$10,570 | $840 | $2,190 | $51,045 | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Personnel Changes Savings | Ancillary Material Cost Savings | One-time Revenue or Avoided Cost Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs