Assessment Year 2015
Principal Product winches
NAICS 333924: Industrial Truck, Tractor, Trailer, and Stacker Machinery Manufacturing
SIC 3531: Construction Machinery and Equipment
Sales Range $10
M
to 50
M
# of Employees 105
Plant Area 123,000
ft2
Annual Production 5,000
pieces
Production Hrs. Annual 1,984
hrs
Location (State) Texas

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $113,471 1,686,544
kWh
Electricity Demand $33,374 6,602
kW-mo/yr
Electricity Fees $23,245 -
Natural Gas $27,387 3,269
MMBtu
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $36,345 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $9,090

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings Ancillary Material Cost Savings
01 3.6193: Install equipment (eg compactor) to reduce disposal costs $16,880 $30,000 - - $16,880
02 4.426: Modify workload $8,280 - - - $8,280
03 2.7142: Utilize higher efficiency lamps and/or ballasts $7,810 $28,220 $4,210
62,870
kWh
$3,600
-
kW-mo/yr
-
04 2.4231: Reduce the pressure of compressed air to the minimum required $1,720 $3,060 $810
12,060
kWh
$910
-
kW-mo/yr
-
05 2.7124: Make a practice of turning off lights when not needed $870 - $470
7,000
kWh
$400
-
kW-mo/yr
-
06 2.3312: Install efficient rectifiers $375 $2,000 $175
2,610
kWh
$200
-
kW-mo/yr
-
07 2.7135: Install occupancy sensors $280 $630 $280
4,170
kWh
- -
08 2.7124: Make a practice of turning off lights when not needed $130 - $70
1,000
kWh
$60
-
kW-mo/yr
-
TOTAL RECOMMENDED $36,345 $63,910 $6,015
89,710
kWh
$5,170
-
kW-mo/yr
$25,160
TOTAL IMPLEMENTED $9,090 $28,850 $5,030
75,040
kWh
$4,060
-
kW-mo/yr
-
Yearly Savings* Imp'd Cost* Electricity Usage Savings Electricity Demand Savings Ancillary Material Cost Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs