Assessment Year | 2015 |
---|---|
Principal Product | metal fabrication and machine shop |
NAICS | 332999: All Other Miscellaneous Fabricated Metal Product Manufacturing |
SIC | 3499: Fabricated Metal Products, Not Elsewhere Classified |
Sales Range | $5 M to 10M |
# of Employees | 35 |
Plant Area |
50,000
ft2
|
Annual Production | 20,000
lb
|
Production Hrs. Annual | 2,000
hrs
|
Location (State) | Texas |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $22,545 | 464,660 |
kWh
|
$0.049 |
Electricity Demand | $19,523 | 2,223 |
kW-mo/yr
|
$8.78 |
Electricity Fees | $5,509 | - |
|
- |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $27,348 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $23,086 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | One-time Revenue or Avoided Cost Savings |
---|---|---|---|---|---|---|---|---|
01 | 2.8121: Apply for tax-free status for energy purchases | $18,605 | $1,975 | - | - | $3,721 | $14,884 | |
02 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $3,525 | $15,240 |
$1,840
34,067
kWh
|
$1,685
-
kW-mo/yr
|
- | - | |
03 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $3,260 | $1,000 |
$1,700
31,490
kWh
|
$1,560
-
kW-mo/yr
|
- | - | |
04 | 2.7122: Disconnect ballasts | $809 | $188 |
$421
7,788
kWh
|
$388
-
kW-mo/yr
|
- | - | |
05 | 2.4231: Reduce the pressure of compressed air to the minimum required | $683 | $13 |
$295
5,458
kWh
|
$388
-
kW-mo/yr
|
- | - | |
06 | 2.4322: Use or replace with energy efficient substitutes | $247 | $863 |
$247
4,573
kWh
|
- | - | - | |
07 | 2.7224: Reduce space conditioning during non-working hours | $165 | $142 |
$165
3,047
kWh
|
- | - | - | |
08 | 2.4314: Use synthetic lubricant | $40 | - |
$16
295
kWh
|
$24
-
kW-mo/yr
|
- | - | |
09 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $14 | - |
$7
140
kWh
|
$7
-
kW-mo/yr
|
- | - | |
TOTAL RECOMMENDED | $27,348 | $19,421 |
$4,691
86,858
kWh
|
$4,052
-
kW-mo/yr
|
$3,721 | $14,884 | ||
TOTAL IMPLEMENTED | $23,086 | $4,168 |
$2,533
46,898
kWh
|
$1,948
-
kW-mo/yr
|
$3,721 | $14,884 | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | One-time Revenue or Avoided Cost Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs