Assessment Year | 2015 |
---|---|
Principal Product | Millwork, pre-hung doors |
NAICS | 321911: Wood Window and Door Manufacturing |
SIC | 2431: Millwork |
Sales Range | $10 M to 50M |
# of Employees | 140 |
Plant Area |
110,000
ft2
|
Annual Production | 160,000
pieces
|
Production Hrs. Annual | 2,772
hrs
|
Location (State) | Texas |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $90,157 | 1,111,500 |
kWh
|
$0.081 |
Electricity Demand | $15,143 | 3,929 |
kW-mo/yr
|
$3.85 |
Electricity Fees | $10,636 | - |
|
- |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $72,760 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $64,930 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Personnel Changes Savings | One-time Revenue or Avoided Cost Savings |
---|---|---|---|---|---|---|---|---|---|
01 | 2.7234: Use heat pump for space conditioning | $11,400 | $10,770 |
$10,680
130,340
kWh
|
$720
-
kW-mo/yr
|
- | - | - | |
02 | 2.8121: Apply for tax-free status for energy purchases | $44,200 | $15,000 | - | - | $8,840 | - | $35,360 | |
03 | 2.7145: Install skylights | $6,800 | $11,100 |
$6,800
82,800
kWh
|
- | - | - | - | |
04 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $4,880 | $2,500 |
$4,140
50,500
kWh
|
$740
-
kW-mo/yr
|
- | - | - | |
05 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $2,160 | $1,180 |
$590
7,140
kWh
|
$30
-
kW-mo/yr
|
- | $1,540 | - | |
06 | 2.6218: Turn off equipment when not in use | $1,600 | - |
$1,360
16,540
kWh
|
$240
-
kW-mo/yr
|
- | - | - | |
07 | 2.4231: Reduce the pressure of compressed air to the minimum required | $930 | $10 |
$790
9,600
kWh
|
$140
-
kW-mo/yr
|
- | - | - | |
08 | 2.7121: Utilize daylight whenever possible in lieu of artificial light | $480 | - |
$480
5,890
kWh
|
- | - | - | - | |
09 | 2.7111: Reduce illumination to minimum necessary levels | $210 | $100 |
$190
2,370
kWh
|
$20
-
kW-mo/yr
|
- | - | - | |
10 | 2.7135: Install occupancy sensors | $100 | $100 |
$100
1,160
kWh
|
- | - | - | - | |
TOTAL RECOMMENDED | $72,760 | $40,760 |
$25,130
306,340
kWh
|
$1,890
-
kW-mo/yr
|
$8,840 | $1,540 | $35,360 | ||
TOTAL IMPLEMENTED | $64,930 | $29,550 |
$17,440
212,780
kWh
|
$1,750
-
kW-mo/yr
|
$8,840 | $1,540 | $35,360 | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Personnel Changes Savings | One-time Revenue or Avoided Cost Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs