Assessment Year | 2015 |
---|---|
Principal Product | Threaded pipe coupling |
NAICS | 332999: All Other Miscellaneous Fabricated Metal Product Manufacturing |
SIC | 3494: Valves and Pipe Fittings, Not Elsewhere Classified |
Sales Range | $10 M to 50M |
# of Employees | 131 |
Plant Area |
45,500
ft2
|
Annual Production | 300,000
pieces
|
Production Hrs. Annual | 2,500
hrs
|
Location (State) | Texas |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $263,122 | 6,369,144 |
kWh
|
$0.041 |
Electricity Demand | $176,528 | 13,305 |
kW-mo/yr
|
$13.27 |
Electricity Fees | $2,668 | - |
|
- |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $71,836 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | - |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings |
---|---|---|---|---|---|---|---|
01 | 2.7221: Lower temperature during the winter season and vice-versa | $24,700 | - |
$10,700
242,400
kWh
|
$14,000
-
kW-mo/yr
|
- | |
02 | 2.1311: Replace electrically-operated equipment with fossil fuel equipment | $14,370 | - |
$33,400
758,000
kWh
|
$21,470
-
kW-mo/yr
|
$(-40,500.0)
-
MMBtu
|
|
03 | 2.4239: Eliminate or reduce compressed air usage | $14,080 | $2,200 |
$6,080
138,220
kWh
|
$8,000
-
kW-mo/yr
|
- | |
04 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $12,800 | $6,740 |
$5,500
125,800
kWh
|
$7,300
-
kW-mo/yr
|
- | |
05 | 2.4231: Reduce the pressure of compressed air to the minimum required | $5,410 | $11 |
$1,820
41,400
kWh
|
$3,590
-
kW-mo/yr
|
- | |
06 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $476 | $1,545 |
$206
4,680
kWh
|
$270
-
kW-mo/yr
|
- | |
TOTAL RECOMMENDED | $71,836 | $10,496 |
$57,706
1,310,500
kWh
|
$54,630
-
kW-mo/yr
|
$(-40,500.0)
-
MMBtu
|
||
TOTAL IMPLEMENTED | - | - | - | - | - | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs