Assessment Year 2015
Principal Product Chairs
NAICS 337214: Office Furniture (except Wood) Manufacturing
SIC 2522: Office Furniture, Except Wood
Sales Range $10
M
to 50
M
# of Employees 85
Plant Area 51,000
ft2
Annual Production 1,300,000
pieces
Production Hrs. Annual 2,530
hrs
Location (State) Texas

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $30,569 443,927
kWh
Electricity Demand $3,563 1,742
kW-mo/yr
Electricity Fees $4,120 -
Natural Gas $5,942 713
MMBtu
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $17,230 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $6,580

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings
01 2.7142: Utilize higher efficiency lamps and/or ballasts $9,680 $8,610 $5,250
99,740
kWh
$4,430
-
kW-mo/yr
02 2.4231: Reduce the pressure of compressed air to the minimum required $4,280 $10 $2,320
44,050
kWh
$1,960
-
kW-mo/yr
03 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves $1,800 $1,000 $980
18,620
kWh
$820
-
kW-mo/yr
04 2.4111: Utilize energy-efficient belts and other improved mechanisms $800 - $370
7,120
kWh
$430
-
kW-mo/yr
05 2.4314: Use synthetic lubricant $390 - $190
3,680
kWh
$200
-
kW-mo/yr
06 2.7135: Install occupancy sensors $170 $110 $110
2,050
kWh
$60
-
kW-mo/yr
07 2.6218: Turn off equipment when not in use $110 - $110
2,160
kWh
-
TOTAL RECOMMENDED $17,230 $9,730 $9,330
177,420
kWh
$7,900
-
kW-mo/yr
TOTAL IMPLEMENTED $6,580 $1,010 $3,600
68,510
kWh
$2,980
-
kW-mo/yr
Yearly Savings* Imp'd Cost* Electricity Usage Savings Electricity Demand Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs