Assessment Year | 2015 |
---|---|
Principal Product | Dryer vents and accessories |
NAICS | 332322: Sheet Metal Work Manufacturing |
SIC | 3444: Sheet Metal Work |
Sales Range | $10 M to 50M |
# of Employees | 105 |
Plant Area |
150,000
ft2
|
Annual Production | 500,000
pieces
|
Production Hrs. Annual | 4,625
hrs
|
Location (State) | Texas |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $97,560 | 1,647,220 |
kWh
|
$0.059 |
Electricity Demand | $90,019 | 5,406 |
kW-mo/yr
|
$16.65 |
Electricity Fees | $5,467 | - |
|
- |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $29,550 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $29,550 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Personnel Changes Savings | One-time Revenue or Avoided Cost Savings |
---|---|---|---|---|---|---|---|---|---|
01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $17,460 | $23,910 |
$12,490
211,760
kWh
|
$4,970
-
kW-mo/yr
|
- | - | - | |
02 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $4,170 | $500 |
$3,060
51,880
kWh
|
$1,110
-
kW-mo/yr
|
- | - | - | |
03 | 2.3212: Optimize plant power factor | $2,800 | $5,010 | - |
$2,800
-
kW-mo/yr
|
- | - | - | |
04 | 2.4231: Reduce the pressure of compressed air to the minimum required | $2,510 | $2 |
$1,840
31,160
kWh
|
$670
-
kW-mo/yr
|
- | - | - | |
05 | 2.8121: Apply for tax-free status for energy purchases | $1,460 | $500 | - | - | $760 | - | $700 | |
06 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $425 | $165 |
$100
1,754
kWh
|
$25
-
kW-mo/yr
|
- | $300 | - | |
07 | 2.7124: Make a practice of turning off lights when not needed | $370 | - |
$370
6,300
kWh
|
- | - | - | - | |
08 | 2.4314: Use synthetic lubricant | $355 | - |
$260
4,402
kWh
|
$95
-
kW-mo/yr
|
- | - | - | |
TOTAL RECOMMENDED | $29,550 | $30,087 |
$18,120
307,256
kWh
|
$9,670
-
kW-mo/yr
|
$760 | $300 | $700 | ||
TOTAL IMPLEMENTED | $29,550 | $30,087 |
$18,120
307,256
kWh
|
$9,670
-
kW-mo/yr
|
$760 | $300 | $700 | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Personnel Changes Savings | One-time Revenue or Avoided Cost Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs