| Assessment Year | 2014 |
|---|---|
| Principal Product | Machining job shop |
| NAICS | 332710: Machine Shops |
| SIC | 3599: Industrial and Commercial Machinery and Equipment, Not Elsewhere Classified |
| Sales Range | $10 M to 50M |
| # of Employees | 80 |
| Plant Area |
42,000
ft2
|
| Annual Production | 2,000
pieces
|
| Production Hrs. Annual | 3,368
hrs
|
| Location (State) | Texas |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $25,079 | 420,248 |
kWh
|
$0.060 |
| Electricity Demand | $12,431 | 1,998 |
kW-mo/yr
|
$6.22 |
| Electricity Fees | $3,215 | - |
|
- |
| LPG | $10,882 | 395 |
MMBtu
|
$27.55 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $28,810 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $12,795 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Ancillary Material Cost Savings | One-time Revenue or Avoided Cost Savings |
|---|---|---|---|---|---|---|---|---|---|
| 01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $5,260 | $10,630 |
$4,100
63,200
kWh
|
$1,160
-
kW-mo/yr
|
- | - | - | |
| 02 | 2.4239: Eliminate or reduce compressed air usage | $3,160 | $1,190 |
$2,460
37,800
kWh
|
$700
-
kW-mo/yr
|
- | - | - | |
| 03 | 2.8121: Apply for tax-free status for energy purchases | $14,335 | $3,000 | - | - | $2,867 | - | $11,468 | |
| 04 | 2.7124: Make a practice of turning off lights when not needed | $1,850 | $660 |
$1,440
22,176
kWh
|
$410
-
kW-mo/yr
|
- | - | - | |
| 05 | 2.3134: Shift from daytime to nighttime operation | $1,680 | - | - |
$1,680
-
kW-mo/yr
|
- | - | - | |
| 06 | 2.4231: Reduce the pressure of compressed air to the minimum required | $830 | $8 |
$590
9,080
kWh
|
$240
-
kW-mo/yr
|
- | - | - | |
| 07 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $645 | $355 |
$50
770
kWh
|
$15
-
kW-mo/yr
|
- | $580 | - | |
| 08 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $550 | $810 |
$450
6,940
kWh
|
$100
-
kW-mo/yr
|
- | - | - | |
| 09 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $500 | $200 |
$390
6,040
kWh
|
$110
-
kW-mo/yr
|
- | - | - | |
| TOTAL RECOMMENDED | $28,810 | $16,853 |
$9,480
146,006
kWh
|
$4,415
-
kW-mo/yr
|
$2,867 | $580 | $11,468 | ||
| TOTAL IMPLEMENTED | $12,795 | $13,853 |
$9,480
146,006
kWh
|
$2,735
-
kW-mo/yr
|
- | $580 | - | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Ancillary Material Cost Savings | One-time Revenue or Avoided Cost Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs