Assessment Year | 2014 |
---|---|
Principal Product | Machining job shop |
NAICS | 332710: Machine Shops |
SIC | 3599: Industrial and Commercial Machinery and Equipment, Not Elsewhere Classified |
Sales Range | $10 M to 50M |
# of Employees | 80 |
Plant Area |
42,000
ft2
|
Annual Production | 2,000
pieces
|
Production Hrs. Annual | 3,368
hrs
|
Location (State) | Texas |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $25,079 | 420,248 |
kWh
|
$0.060 |
Electricity Demand | $12,431 | 1,998 |
kW-mo/yr
|
$6.22 |
Electricity Fees | $3,215 | - |
|
- |
LPG | $10,882 | 395 |
MMBtu
|
$27.55 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $28,810 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $12,795 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Ancillary Material Cost Savings | One-time Revenue or Avoided Cost Savings |
---|---|---|---|---|---|---|---|---|---|
01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $5,260 | $10,630 |
$4,100
63,200
kWh
|
$1,160
-
kW-mo/yr
|
- | - | - | |
02 | 2.4239: Eliminate or reduce compressed air usage | $3,160 | $1,190 |
$2,460
37,800
kWh
|
$700
-
kW-mo/yr
|
- | - | - | |
03 | 2.8121: Apply for tax-free status for energy purchases | $14,335 | $3,000 | - | - | $2,867 | - | $11,468 | |
04 | 2.7124: Make a practice of turning off lights when not needed | $1,850 | $660 |
$1,440
22,176
kWh
|
$410
-
kW-mo/yr
|
- | - | - | |
05 | 2.3134: Shift from daytime to nighttime operation | $1,680 | - | - |
$1,680
-
kW-mo/yr
|
- | - | - | |
06 | 2.4231: Reduce the pressure of compressed air to the minimum required | $830 | $8 |
$590
9,080
kWh
|
$240
-
kW-mo/yr
|
- | - | - | |
07 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $645 | $355 |
$50
770
kWh
|
$15
-
kW-mo/yr
|
- | $580 | - | |
08 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $550 | $810 |
$450
6,940
kWh
|
$100
-
kW-mo/yr
|
- | - | - | |
09 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $500 | $200 |
$390
6,040
kWh
|
$110
-
kW-mo/yr
|
- | - | - | |
TOTAL RECOMMENDED | $28,810 | $16,853 |
$9,480
146,006
kWh
|
$4,415
-
kW-mo/yr
|
$2,867 | $580 | $11,468 | ||
TOTAL IMPLEMENTED | $12,795 | $13,853 |
$9,480
146,006
kWh
|
$2,735
-
kW-mo/yr
|
- | $580 | - | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Ancillary Material Cost Savings | One-time Revenue or Avoided Cost Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs