Assessment Year | 2014 |
---|---|
Principal Product | Hamburger buns |
NAICS | 311812: Commercial Bakeries |
SIC | 2051: Bread and Other Bakery Products, Except Cookies and Crackers |
Sales Range | $50 M to 100M |
# of Employees | 110 |
Plant Area |
150,000
ft2
|
Annual Production | 760,000,000
pieces
|
Production Hrs. Annual | 7,488
hrs
|
Location (State) | Mississippi |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $584,122 | 9,920,200 |
kWh
|
$0.059 |
Electricity Demand | $92,033 | 16,684 |
kW-mo/yr
|
$5.52 |
Electricity Fees | $10,736 | - |
|
- |
Natural Gas | $305,443 | 51,745 |
MMBtu
|
$5.90 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $75,170 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $21,200 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings |
---|---|---|---|---|---|---|
01 | 2.4322: Use or replace with energy efficient substitutes | $48,700 | $3,340 |
$36,600
691,000
kWh
|
$12,100
-
kW-mo/yr
|
|
02 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $15,250 | $2,500 |
$11,450
216,000
kWh
|
$3,800
-
kW-mo/yr
|
|
03 | 2.4133: Use most efficient type of electric motors | $4,840 | $33,524 |
$3,640
68,680
kWh
|
$1,200
-
kW-mo/yr
|
|
04 | 2.4231: Reduce the pressure of compressed air to the minimum required | $4,820 | $9 |
$3,620
68,300
kWh
|
$1,200
-
kW-mo/yr
|
|
05 | 2.7124: Make a practice of turning off lights when not needed | $1,110 | - |
$1,110
20,930
kWh
|
- | |
06 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $450 | $60 |
$340
6,360
kWh
|
$110
-
kW-mo/yr
|
|
TOTAL RECOMMENDED | $75,170 | $39,433 |
$56,760
1,071,270
kWh
|
$18,410
-
kW-mo/yr
|
||
TOTAL IMPLEMENTED | $21,200 | $36,024 |
$16,200
305,610
kWh
|
$5,000
-
kW-mo/yr
|
||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs