Assessment Year 2014
Principal Product All terrain oil industry vehicles
NAICS 336120: Heavy Duty Truck Manufacturing
SIC 3711: Motor Vehicles and Passenger Car Bodies
Sales Range $100
M
to 500
M
# of Employees 200
Plant Area 56,000
ft2
Annual Production 120
pieces
Production Hrs. Annual 3,175
hrs
Location (State) Texas

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $90,672 1,581,360
kWh
Electricity Demand $76,212 6,887
kW-mo/yr
Electricity Fees $(-3,843.0) -
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $38,998 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $24,480

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings
01 2.7142: Utilize higher efficiency lamps and/or ballasts $13,960 $24,700 $8,200
143,000
kWh
$5,760
-
kW-mo/yr
02 2.3131: Reschedule plant operations or reduce load to avoid peaks $9,000 - - $9,000
-
kW-mo/yr
03 2.7121: Utilize daylight whenever possible in lieu of artificial light $5,730 - $5,730
100,000
kWh
-
04 2.4231: Reduce the pressure of compressed air to the minimum required $4,790 $55 $2,810
49,000
kWh
$1,980
-
kW-mo/yr
05 2.7124: Make a practice of turning off lights when not needed $3,445 - $3,445
60,135
kWh
-
06 2.7232: Replace existing hvac unit with high efficiency model $1,158 $4,500 $495
6,005
kWh
$663
-
kW-mo/yr
07 2.7145: Install skylights $915 $4,140 $915
15,955
kWh
-
TOTAL RECOMMENDED $38,998 $33,395 $21,595
374,095
kWh
$17,403
-
kW-mo/yr
TOTAL IMPLEMENTED $24,480 $24,755 $16,740
292,000
kWh
$7,740
-
kW-mo/yr
Yearly Savings* Imp'd Cost* Electricity Usage Savings Electricity Demand Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs