Assessment Year | 2014 |
---|---|
Principal Product | Steel and plastic composite drums and containers |
NAICS | 332439: Other Metal Container Manufacturing |
SIC | 3412: Metal Shipping Barrels, Drums, Kegs, and Pails |
Sales Range | $10 M to 50M |
# of Employees | 135 |
Plant Area |
350,000
ft2
|
Annual Production | 3,720,000
pieces
|
Production Hrs. Annual | 8,544
hrs
|
Location (State) | Texas |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $301,912 | 7,156,669 |
kWh
|
$0.042 |
Electricity Demand | $145,102 | 15,797 |
kW-mo/yr
|
$9.19 |
Electricity Fees | $10,301 | - |
|
- |
Natural Gas | $540,810 | 123,472 |
MMBtu
|
$4.38 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $249,045 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $117,400 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Personnel Changes Savings | Primary Product Savings |
---|---|---|---|---|---|---|---|---|
01 | 4.652: Replace existing equipment with more suitable substitutes | $112,575 | $24,000 | - | - | - | $112,575 | |
02 | 4.445: Install equipment to move product | $108,485 | $9,000 |
$(-450.0)
(-9,730)
kWh
|
$(-145.0)
-
kW-mo/yr
|
$109,080 | - | |
03 | 2.4231: Reduce the pressure of compressed air to the minimum required | $13,490 | $150 |
$10,590
230,130
kWh
|
$2,900
-
kW-mo/yr
|
- | - | |
04 | 2.2511: Insulate bare equipment | $8,110 | $200 |
$6,360
138,300
kWh
|
$1,750
-
kW-mo/yr
|
- | - | |
05 | 2.4314: Use synthetic lubricant | $3,690 | - |
$2,830
61,570
kWh
|
$860
-
kW-mo/yr
|
- | - | |
06 | 2.7124: Make a practice of turning off lights when not needed | $790 | - |
$590
12,920
kWh
|
$200
-
kW-mo/yr
|
- | - | |
07 | 2.4239: Eliminate or reduce compressed air usage | $770 | $60 |
$610
13,240
kWh
|
$160
-
kW-mo/yr
|
- | - | |
08 | 2.7121: Utilize daylight whenever possible in lieu of artificial light | $650 | - |
$650
14,100
kWh
|
- | - | - | |
09 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $250 | $55 |
$160
3,510
kWh
|
$90
-
kW-mo/yr
|
- | - | |
10 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $235 | $30 |
$185
4,030
kWh
|
$50
-
kW-mo/yr
|
- | - | |
TOTAL RECOMMENDED | $249,045 | $33,495 |
$21,525
468,070
kWh
|
$5,865
-
kW-mo/yr
|
$109,080 | $112,575 | ||
TOTAL IMPLEMENTED | $117,400 | $24,085 |
$3,825
83,210
kWh
|
$1,000
-
kW-mo/yr
|
- | $112,575 | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Personnel Changes Savings | Primary Product Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs