Assessment Year | 2013 |
---|---|
Principal Product | Dairy products |
NAICS | 311520: Ice Cream and Frozen Dessert Manufacturing |
SIC | 2024: Ice Cream and Frozen Desserts |
Sales Range | $100 M to 500M |
# of Employees | 326 |
Plant Area |
100,000
ft2
|
Annual Production | 29,000
Tgal
|
Production Hrs. Annual | 8,688
hrs
|
Location (State) | Texas |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $477,640 | 10,123,500 |
kWh
|
$0.047 |
Electricity Demand | $173,539 | 17,626 |
kW-mo/yr
|
$9.85 |
Electricity Fees | $12,024 | - |
|
- |
Natural Gas | $154,497 | 27,116 |
MMBtu
|
$5.70 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $57,374 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $52,230 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Primary Raw Material Savings | Ancillary Material Cost Savings |
---|---|---|---|---|---|---|---|---|---|
01 | 2.2121: Increase amount of condensate returned | $34,060 | $250,000 | - | - |
$7,310
-
MMBtu
|
$23,900 | $2,850 | |
02 | 2.4231: Reduce the pressure of compressed air to the minimum required | $12,370 | $50 |
$9,260
197,000
kWh
|
$3,110
-
kW-mo/yr
|
- | - | - | |
03 | 2.7135: Install occupancy sensors | $2,700 | $1,800 |
$2,020
43,000
kWh
|
$680
-
kW-mo/yr
|
- | - | - | |
04 | 2.2511: Insulate bare equipment | $1,940 | $235 | - | - |
$1,940
-
MMBtu
|
- | - | |
05 | 2.1233: Analyze flue gas for proper air/fuel ratio | $1,900 | $500 | - | - |
$1,900
-
MMBtu
|
- | - | |
06 | 2.1233: Analyze flue gas for proper air/fuel ratio | $1,960 | $500 | - | - |
$1,960
-
MMBtu
|
- | - | |
07 | 2.4314: Use synthetic lubricant | $1,887 | - |
$1,355
28,833
kWh
|
$532
-
kW-mo/yr
|
- | - | - | |
08 | 2.4239: Eliminate or reduce compressed air usage | $307 | $157 |
$125
2,650
kWh
|
$182
-
kW-mo/yr
|
- | - | - | |
09 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $250 | $126 |
$190
4,000
kWh
|
$60
-
kW-mo/yr
|
- | - | - | |
TOTAL RECOMMENDED | $57,374 | $253,368 |
$12,950
275,483
kWh
|
$4,564
-
kW-mo/yr
|
$13,110
-
MMBtu
|
$23,900 | $2,850 | ||
TOTAL IMPLEMENTED | $52,230 | $251,285 |
$9,260
197,000
kWh
|
$3,110
-
kW-mo/yr
|
$13,110
-
MMBtu
|
$23,900 | $2,850 | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Primary Raw Material Savings | Ancillary Material Cost Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs