Assessment Year | 2013 |
---|---|
Principal Product | Doors |
NAICS | 321911: Wood Window and Door Manufacturing |
SIC | 2431: Millwork |
Sales Range | $10 M to 50M |
# of Employees | 55 |
Plant Area |
84,600
ft2
|
Annual Production | 890,000
pieces
|
Production Hrs. Annual | 2,030
hrs
|
Location (State) | Texas |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $75,239 | 1,515,391 |
kWh
|
$0.050 |
Electricity Demand | $50,903 | 7,756 |
kW-mo/yr
|
$6.56 |
Electricity Fees | $8,190 | - |
|
- |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $179,110 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $34,555 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Solid Waste (non-haz) Savings | Administrative Changes Savings | Primary Raw Material Savings |
---|---|---|---|---|---|---|---|---|---|
01 | 3.5317: Sell / offer by-product as animal feed | $143,455 | $102,715 | - | - |
$84,240
-
lb
|
$59,215 | - | |
02 | 3.2123: Convert to high volume low pressure (hvlp) paint guns | $17,500 | $800 | - | - | - | - | $17,500 | |
03 | 2.3212: Optimize plant power factor | $10,090 | $12,690 | - |
$10,090
-
kW-mo/yr
|
- | - | - | |
04 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $520 | $160 |
$270
5,400
kWh
|
$250
-
kW-mo/yr
|
- | - | - | |
05 | 2.4231: Reduce the pressure of compressed air to the minimum required | $1,100 | $16 |
$570
11,360
kWh
|
$530
-
kW-mo/yr
|
- | - | - | |
06 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $5,420 | $1,000 |
$2,800
55,900
kWh
|
$2,620
-
kW-mo/yr
|
- | - | - | |
07 | 2.6218: Turn off equipment when not in use | $780 | - |
$780
15,600
kWh
|
- | - | - | - | |
08 | 2.7121: Utilize daylight whenever possible in lieu of artificial light | $245 | - |
$125
2,500
kWh
|
$120
-
kW-mo/yr
|
- | - | - | |
TOTAL RECOMMENDED | $179,110 | $117,381 |
$4,545
90,760
kWh
|
$13,610
-
kW-mo/yr
|
$84,240
-
lb
|
$59,215 | $17,500 | ||
TOTAL IMPLEMENTED | $34,555 | $14,650 |
$3,975
79,400
kWh
|
$13,080
-
kW-mo/yr
|
- | - | $17,500 | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Solid Waste (non-haz) Savings | Administrative Changes Savings | Primary Raw Material Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs