| Assessment Year | 2012 |
|---|---|
| Principal Product | Bricks |
| NAICS | 327120: Clay Building Material and Refractories Manufacturing |
| SIC | 3251: Brick and Structural Clay Tile |
| Sales Range | $5 M to 10M |
| # of Employees | 60 |
| Plant Area |
100,000
ft2
|
| Annual Production | 125,000,000
pieces
|
| Production Hrs. Annual | 8,736
hrs
|
| Location (State) | Texas |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $633,695 | 11,266,950 |
kWh
|
$0.056 |
| Electricity Demand | $134,694 | 31,128 |
kW-mo/yr
|
$4.33 |
| Electricity Fees | $2,148 | - |
|
- |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $33,129 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $27,714 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Personnel Changes Savings | Administrative Changes Savings | Ancillary Material Cost Savings |
|---|---|---|---|---|---|---|---|---|---|
| 01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $18,450 | $58,400 |
$14,750
295,000
kWh
|
$3,700
-
kW-mo/yr
|
- | - | - | |
| 02 | 2.7124: Make a practice of turning off lights when not needed | $7,470 | - |
$6,550
131,000
kWh
|
$920
-
kW-mo/yr
|
- | - | - | |
| 03 | 2.4314: Use synthetic lubricant | $2,900 | - |
$2,335
46,700
kWh
|
$565
-
kW-mo/yr
|
- | - | - | |
| 04 | 2.4231: Reduce the pressure of compressed air to the minimum required | $1,410 | $60 |
$1,080
21,700
kWh
|
$330
-
kW-mo/yr
|
- | - | - | |
| 05 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $1,105 | $512 |
$155
3,130
kWh
|
$15
-
kW-mo/yr
|
$935 | - | - | |
| 06 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $1,055 | $500 |
$780
15,600
kWh
|
$275
-
kW-mo/yr
|
- | - | - | |
| 07 | 2.8123: Pay utility bills on time | $402 | - | - | - | - | $402 | - | |
| 08 | 3.5248: Separate and recycle scrap metal to foundry or for sale | $337 | - | - | - | - | - | $337 | |
| TOTAL RECOMMENDED | $33,129 | $59,472 |
$25,650
513,130
kWh
|
$5,805
-
kW-mo/yr
|
$935 | $402 | $337 | ||
| TOTAL IMPLEMENTED | $27,714 | $58,900 |
$22,080
441,600
kWh
|
$4,895
-
kW-mo/yr
|
- | $402 | $337 | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Personnel Changes Savings | Administrative Changes Savings | Ancillary Material Cost Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs