Assessment Year | 2011 |
---|---|
Principal Product | Envelopes |
NAICS | 322230: Stationery Product Manufacturing |
SIC | 2677: Envelopes |
Sales Range | $50 M to 100M |
# of Employees | 350 |
Plant Area |
315,000
ft2
|
Annual Production | 4,800,000,000
pieces
|
Production Hrs. Annual | 7,248
hrs
|
Location (State) | Texas |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $1,722,467 | 21,910,000 |
kWh
|
$0.079 |
Electricity Demand | $269,953 | 39,516 |
kW-mo/yr
|
$6.83 |
Electricity Fees | $52,580 | - |
|
- |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $113,629 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $113,629 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings |
---|---|---|---|---|---|---|---|
01 | 2.3212: Optimize plant power factor | $50,712 | $92,850 | - |
$50,712
-
kW-mo/yr
|
- | |
02 | 2.8123: Pay utility bills on time | $19,975 | - | - | - | $19,975 | |
03 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $14,800 | $900 |
$12,900
163,798
kWh
|
$1,900
-
kW-mo/yr
|
- | |
04 | 2.6218: Turn off equipment when not in use | $11,000 | - |
$11,000
140,000
kWh
|
- | - | |
05 | 2.4314: Use synthetic lubricant | $10,722 | - |
$9,352
118,378
kWh
|
$1,370
-
kW-mo/yr
|
- | |
06 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $3,920 | $680 |
$3,420
43,300
kWh
|
$500
-
kW-mo/yr
|
- | |
07 | 2.7135: Install occupancy sensors | $2,500 | $1,700 |
$2,500
32,000
kWh
|
- | - | |
TOTAL RECOMMENDED | $113,629 | $96,130 |
$39,172
497,476
kWh
|
$54,482
-
kW-mo/yr
|
$19,975 | ||
TOTAL IMPLEMENTED | $113,629 | $96,130 |
$39,172
497,476
kWh
|
$54,482
-
kW-mo/yr
|
$19,975 | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs