Assessment Year | 2010 |
---|---|
Principal Product | Plastic profile extrusions |
NAICS | 326121: Unlaminated Plastics Profile Shape Manufacturing |
SIC | 3089: Plastics Products, Not Elsewhere Classified |
Sales Range | $10 M to 50M |
# of Employees | 50 |
Plant Area |
87,540
ft2
|
Annual Production | 648,000
lb
|
Production Hrs. Annual | 5,400
hrs
|
Location (State) | Texas |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $170,836 | 2,324,097 |
kWh
|
$0.074 |
Electricity Demand | $68,249 | 9,978 |
kW-mo/yr
|
$6.84 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $36,205 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | - |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Solid Waste (non-haz) Savings |
---|---|---|---|---|---|---|---|
01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $11,400 | $20,200 |
$9,500
128,000
kWh
|
$1,900
-
kW-mo/yr
|
- | |
02 | 3.5315: Lease / purchase baler; sell cardboard to recycler | $9,140 | - | - | - |
$9,140
-
lb
|
|
03 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $8,290 | $600 |
$6,900
93,600
kWh
|
$1,390
-
kW-mo/yr
|
- | |
04 | 2.3212: Optimize plant power factor | $4,500 | $10,480 | - |
$4,500
-
kW-mo/yr
|
- | |
05 | 2.7124: Make a practice of turning off lights when not needed | $1,950 | $270 |
$1,560
21,070
kWh
|
$390
-
kW-mo/yr
|
- | |
06 | 2.4314: Use synthetic lubricant | $820 | - |
$700
9,400
kWh
|
$120
-
kW-mo/yr
|
- | |
07 | 2.6218: Turn off equipment when not in use | $105 | - |
$105
1,400
kWh
|
- | - | |
TOTAL RECOMMENDED | $36,205 | $31,550 |
$18,765
253,470
kWh
|
$8,300
-
kW-mo/yr
|
$9,140
-
lb
|
||
TOTAL IMPLEMENTED | - | - | - | - | - | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Solid Waste (non-haz) Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs