Assessment Year | 2009 |
---|---|
Principal Product | Plug, butterfly, and ball valves, connectors, pumps |
NAICS | 332911: Industrial Valve Manufacturing |
SIC | 3494: Valves and Pipe Fittings, Not Elsewhere Classified |
Sales Range | $100 M to 500M |
# of Employees | 300 |
Plant Area |
300,000
ft2
|
Annual Production | 1,000,000
pieces
|
Production Hrs. Annual | 3,860
hrs
|
Location (State) | Texas |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $1,755,080 | 18,986,766 |
kWh
|
$0.092 |
Electricity Demand | $328,183 | 65,052 |
kW-mo/yr
|
$5.04 |
Electricity Fees | $45,584 | - |
|
- |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $192,805 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $127,505 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Personnel Changes Savings | Ancillary Material Cost Savings |
---|---|---|---|---|---|---|---|---|
01 | 2.3134: Shift from daytime to nighttime operation | $59,200 | - | - |
$93,800
-
kW-mo/yr
|
$(-34,600.0) | - | |
02 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $48,230 | $111,190 |
$38,530
417,000
kWh
|
$6,750
-
kW-mo/yr
|
- | $2,950 | |
03 | 2.6218: Turn off equipment when not in use | $35,170 | $1,300 |
$30,500
330,000
kWh
|
$4,670
-
kW-mo/yr
|
- | - | |
04 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $32,100 | $3,000 |
$27,300
295,800
kWh
|
$4,800
-
kW-mo/yr
|
- | - | |
05 | 2.4314: Use synthetic lubricant | $6,890 | - |
$5,860
63,380
kWh
|
$1,030
-
kW-mo/yr
|
- | - | |
06 | 2.6218: Turn off equipment when not in use | $4,000 | - |
$4,000
43,400
kWh
|
- | - | - | |
07 | 2.7145: Install skylights | $2,100 | $2,730 |
$2,100
22,800
kWh
|
- | - | - | |
08 | 2.7121: Utilize daylight whenever possible in lieu of artificial light | $1,950 | - |
$1,950
21,100
kWh
|
- | - | - | |
09 | 2.6218: Turn off equipment when not in use | $1,780 | - |
$1,780
19,300
kWh
|
- | - | - | |
10 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $1,385 | $380 |
$260
2,860
kWh
|
$20
-
kW-mo/yr
|
- | $1,105 | |
TOTAL RECOMMENDED | $192,805 | $118,600 |
$112,280
1,215,640
kWh
|
$111,070
-
kW-mo/yr
|
$(-34,600.0) | $4,055 | ||
TOTAL IMPLEMENTED | $127,505 | $115,870 |
$106,180
1,149,440
kWh
|
$17,270
-
kW-mo/yr
|
- | $4,055 | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Personnel Changes Savings | Ancillary Material Cost Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs